°F,°C |
PF 905 Industrial Std Temperature Range
|
| 1100°F - 2730°F |
(600°C - 1500°C) |
|
PF 905 Optional Extended Temperature Ranges:
|
| 1300°F - 3600°F |
(700°C - 2000°C) |
| 1450°F - 4500°F |
(790°C - 2500°C) |
| 1550°F - 5400°F |
(850°C - 3000°C) |
|
PF 1550 Industrial Std Temperature Range:
|
| 480°F - 1470°F |
(250°C - 800°C) |
|
PF 1550 Optional Extended Temperature Ranges:
|
| 525°F - 1650°F |
(275°C - 900°C) |
| 575°F - 2000°F |
(300°C - 1100°C) |
| 660°F - 2100°F |
(350°C - 1150°C) |
|
PF Industrial Dual Temperature Range:
Consult Factory
|
| Several Temperature Ranges Are Available Between |
| 480°F - 5400°F |
(250°C - 3000°C) |
|
|
|
(4) Ranges Available |
|
|
± 5°F (3°C) |
|
|
± 1°F (1°C) |
|
|
± 1°F (1°C) |
Effective Wavelength PF 905:
|
0.905µm ±0.015 |
Effective Wavelength PF 1.550:
|
1.550µm ±0.015 |
Effective Wavelength PF Dual:
|
1.550µm ±0.015 & 0.905µm ±0.015 |
|
|
0.055 µm |
Automatic Emissivity Measuring Range:
|
0.01 -1.0 ( Increments 0.01 ) |
|
Acquisition Time:
|
1ms - 2000ms Selectable |
|
|
40 Digit Readout |
|
|
Provides Emissivity Value (E), & Corrected Temperature (Tt) |
Operation Mode, Single & Interval:
|
Provides Emissivity Value (E), & Uncorrected temperature (Tu), Corrected Temperature (Tt) |
Operation Mode, High Speed:
|
Data is sent directly to 720 reading capacity internal notebook. 40 Digit Readout of Emissivity Value (E), & Uncorrected temperature (Tu), Corrected Temperature (Tt) can be reviewed after all data is acquired in notebook |
Operation Mode, High Speed Transmit:
|
Raw data is sent directly to an external PC via COM port Readout of Emissivity Value (E), & Uncorrected temperature (Tu), Corrected Temperature (Tt) can be viewed on screen as the data is acquired or sent to a file. |
Standard Target Distance:
|
Sensor head can be arranged for fixed focus to accommodate any distance from 1.0' (0.3m) to 10.0' (3.0m) standard.
Special heads and probes can be designed to accommodate most any target distance.
|
Standard Target Sizes Available
|
| Target Size |
Target Distance |
| Min |
Max |
Min |
Max |
| 0.59" (15mm) |
2.28" (58mm) |
6.0' (15cm) |
96"' (243cm) |
|
Special heads and probes can be designed to accommodate most any target size to as low as 0.010" (0.25mm).
|
|
|
|
1, 2, 4, 8, 21, 23, 37 Readings/sec Selectable |
Standard Maximum Operating Temperatures:
Extended Operating Temperatures Available Upon Request
|
| Electronic Enclosure |
32°F (0°C) - 125°F (50°C) |
| Sensor Head |
32°F (0°C) - 480°F (250°C) |
| Fiber Optic Cables |
32°F (0°C) - 250°F (125°C) |
|
Instrument Enclosure:
Special Requirements Available Upon Request
|
| Standard
NEMA 12 Housing |
| Optional NEMA
4X Housing |
| Optional
Explosion Proof |
| Optional
19" Rack Mount Enclosure |
|
|
|
| Single Analog Output: 0 -5vdc, 0-20mA or 4-20mA (Additional analog output available as an option) (Opto Isolated available as an option) |
| Single Digital Output : RS232C (RS485 Opto Isolated available as an option) |
|
|
|
115v/60Hz or 230v/50Hz |
|

- The Pyrofiber®
IR thermometer comes complete factory calibrated traceable to NIST Standards.
- Optional "Certificate of Calibration" per point to NIST Standards can also be provided.
- Expert factory service is also available for periodic calibration.
|
|
Product Information
Model PF905, Pyrofiber® Industrial
Automatic Emissivity Correcting Infrared Thermometer
The Standard Pyrofiber® Industrial (AEMS) comes complete and ready to use with:
|
- Standard Temperature Range
- NEMA 12 Housing
- Keypad, Digital Display
- Electronics
- Operating Software
- Output: One Analog: 0-5VDC or 0-20mA
- Output Digital: RS232
-
Fiber Optic
Sensor and cables
- Target
Distance: To Suit Application
- Target Spot Size: To Suit Application
- Instruction Manual
- Statement Of Calibration
|
 |
- Emissivity Calibration Reflective Standard With Certification, For On-Sight Optical Calibration and Verification of Laser Emissivity Measurements.
- 19" Rack Mount Enclosure
- Lumina Light Source For Installation & Verification of Sensor Head Alignment Complete With Adapter
- "L" Mounting Bracket For Optical Sensor Head
- Opto Isolate Analog Output 0-20mA, 4-20mA, 0 -5vdc
- Opto Isolate Digital Output RS232/RS485
- Secondary Analog Output 0-20mA, 4-20mA, 0 -5vdc
- Certificate Of Calibration (Per Temperature Point)

Good performance and reliability are what you expect when you buy precision products from The Pyrometer Instrument Company, Inc.. The Pyrofiber®
non contact IR thermometer comes complete with a one year factory warranty. For complete details visit our Product Warranty Page.
|