Pyrometer world leader in precision temperature sensors, temperature measurement infrared thermometers, thermocouple thermometers and process automation equipment.

Pyrofiber Laboratory high temperature non contact infrared thermometer ir sensor for temperature measurement and true emissivity measurement.


Pyrofiber Laboratory infrared thermometer high temperature measurement ir sensor

  • High Temperature Infrared Thermometer
  • Automatically Measures Emissivity
  • Accuracy After Emissivity Correction: ± 5°F  (± 3°C)
  • 1ms Data Acquisition Rate
  • 3 Temperature Models Available:
      PF 905: 1100°F - 2730°F (600°C - 1500°C)
      PF 1550:  480°F - 1470°F  (250°C - 800°C)
      PF Dual:  Several Temperature Ranges Available
  • Extended Ranges Available To 3000°C:
  • Internal Data Notebook & PC Interface
  • Analog & Digital Outputs
  • Laboratory Process Control Solution

Classification - temperature measurement, fiber optic sensor, non contact infrared thermometer.

The Pyrofiber® Lab Automatic Emissivity Measurement System (AEMS) non contact infrared thermometer uses the latest fiber optic sensor and pulsed laser technology to precisely measure the true target temperature measurement. While all non contact infrared thermometer instruments measure a target radiance temperature, the  Pyrofiber® Lab dynamically determines a targets emissivity value resulting in unmatched temperature measurement accuracy to ±3° C. With the Pyrofiber® Lab,  extremely accurate temperature measurements can be made.

The Pyrofiber® Lab infrared thermometer incorporates an electronic microprocessor control unit housed in a 19" rack mount enclosure, LCD digital display, membrane keypad, power supply, fiber optic cable and connections with a primary fiber optic sensor head and optional secondary background radiation (irradiance) sensor head.  The Pyrofiber® Lab can be operated from the instrument's keypad or remote control from a PC. The Pyrofiber's® microprocessor control measures radiance, emissivity, and background radiance values at an extremely fast 1ms data acquisition rate. 

Click Here For Detailed Information On Pyrolaser® & Pyrofiber® Unique Technology

The Pyrofiber® Lab automatic emissivity correcting IR thermometer is used for many laboratory applications. This includes high temperature measurement in refractories, ovens, furnaces and vacuum chambers and reactors. Virtually anywhere accurate non contact IR thermometer temperature measurements are required in an laboratory environment. Custom sensor heads and probes are also available to suit your application.
  • Material Testing & Evaluation
  • Research & Development
  • Laboratory High Temperature Applications
  • Refractory Temperature Measurement
  • Induction Heating
  • Ceramic & Graphite Applications
  • Pilot Plant Evaluations

View Product Selection Guide to see
complete line of temperature measurement non contact infrared thermometer products
that measure emissivity including on line temperature control fiber optic sensors
for industrial and laboratory applications.

The Pyrofiber® Lab's main fiber optic sensor head reads the radiance emitted from a hot target.  Pyrofiber®  then fires its pulse laser at the target.  The reflected energy from the laser is then collected They the Pyrofiber®  Lab's main sensor head.  Extraneous background radiation (irradiance) from other sources (Tx) "wall shine readings",  (Optional) can be collected from a secondary sensor head should the application require. The Pyrofiber®  Lab's microprocessor temperature control processes all the data collected (radiance, laser return & wall shine values) and displays the results on the Pyrofiber®  LCD display.  Auto mode displayed data includes corrected temperature measurement (Tt) and emissivity values (E) accurate to ±3°C.



Selectable Readout:

°F,°C

PF 905 Standard Temperature Range:

1100°F - 2730°F (600°C - 1500°C)

PF 905 Optional Extended Temperature Ranges:

1300°F - 3600°F (700°C - 2000°C)
1450°F - 4500°F (790°C - 2500°C)
1550°F - 5400°F (850°C - 3000°C)

PF 1550 Standard Temperature Range:

480°F - 1470°F (250°C - 800°C)

PF 1550 Optional Extended Temperature Ranges:

525°F - 1650°F (275°C - 900°C)
575°F - 2000°F (300°C - 1100°C)
660°F - 2100°F (350°C - 1150°C)

PF 1550 Dual Temperature Ranges:

Consult Factory

Several temperature Ranges Are Available Between
1560°F - 5400°F (850°C - 3000°C)

Calibration Ranges:

(4) Ranges Available

Accuracy:

± 5°F (3°C)

Resolution:

± 1°F (1°C)

Repeatability:

± 1°F (1°C)

Effective Wavelength PF 905:

0.905µm ±0.015

Effective Wavelength PF 1.550:

1.550µm ±0.015

Effective Wavelength PF Dual:

1.550µm ±0.015 & 0.905 µm ±0.015

Bandwidth:

0.055 µm

Automatic Emissivity Measuring Range:

0.01 -1.0 ( Increments 0.01 )

Acquisition Time:

1ms - 2000ms Selectable

LCD Display

40 Digit Readout 

Operation Mode, Auto:

Provides Emissivity Value (E),  &  Corrected Temperature (Tt)

Operation Mode, Single & Interval:

Provides Emissivity Value (E),  & Uncorrected temperature (Tu), Corrected Temperature (Tt)

Operation Mode, High Speed:

Data is sent directly to 720 reading capacity internal notebook. 40 Digit Readout  of Emissivity Value (E),   & Uncorrected temperature (Tu), Corrected Temperature (Tt) can be reviewed after all data is acquired in notebook

Operation Mode, High Speed Transmit:

Raw data is sent directly to an external PC via COM port Readout of Emissivity Value (E),  & Uncorrected temperature (Tu), Corrected Temperature (Tt) can be viewed on screen as the data is acquired or sent to a file.

Standard Target Distance:

Sensor head can be arranged for fixed focus to accommodate any distance from 1.0' (0.3m) to 10.0' (3.0m) standard.

Special heads and probes can be designed to accommodate most any target distance.

Standard Target Sizes Available

 

Target Size Target Distance
Min Max Min Max
0.039" (1mm) 2.0" (50mm) 0.039" (1.0mm) 40" (100cm)

Special heads and probes can be designed to accommodate most any target size to as low as 0.010" (0.25mm).

Sample Rate

1, 2, 4, 8, 21, 23, 37 Readings/sec Selectable

Standard Maximum Operating Temperatures:

Extended Operating Temperatures Available Upon Request

Electronic Enclosure 32°F (0°C) - 125°F (50°C)
Sensor Head 32°F (0°C) - 480°F (250°C)
Fiber Optic Cables 32°F (0°C) - 250°F (125°C)

Instrument Enclosure:

Special Requirements Available Upon Request

Standard 19" Rack Mount Enclosure
Optional Nema 12 Laboratory Housing
Optional NEMA 4X Laboratory Housing
Optional Explosion Proof

Auxiliary Output:

Single Analog Output: 0 -5vdc, 0-20mA or   4-20mA  (Additional analog output available as an option) (Opto Isolated available as an option)
Single Digital Output :  RS232C (RS485 Opto Isolated available as an option)

Power Supply:

115v/60Hz or 230v/50Hz

 

  • The Pyrofiber® Lab IR thermometer comes complete factory calibrated traceable to NIST Standards.
  • Optional "Certificate of Calibration" per point to NIST Standards can also be provided.
  • Expert factory service is also available for periodic calibration.

Pyrofiber Laboratory high temperature non contact infrared thermometer ir sensor for temperature measurement and true emissivity measurement.

Model PF905, Pyrofiber® Laboratory Automatic Emissivity Correcting Infrared Thermometer. The Standard Pyrofiber® Laboratory (AEMS) comes complete and ready to use with:

  • Standard Temperature Range
  • 19" Rack Mount Enclosure
  • Keypad, Digital Display
  • Electronics
  • Fiber Optic Sensor Head and cables
  • Operating Software
  • Output: One Analog: 0-5VDC or 0-20mA
  • Output Digital: RS232
  • Target Distance: To Suit Application
  • Target Spot Size: To Suit Application
  • Instruction Manual
  • Statement Of Calibration

  • Emissivity Calibration Reflective Standard With Certification, For On-Sight Optical Calibration and Verification of Laser Emissivity Measurements.
  • NEMA 12 or 4x Industrial Housings
  • Lumina Light Source For Installation & Verification of Sensor Head Alignment Complete With Adapter
  • "L" Mounting Bracket For Optical Sensor Head
  • Opto Isolate Analog Output 0-20mA,  4-20mA, 0 -5vdc
  • Opto Isolate Digital Output RS232/RS485
  • Secondary Analog Output 0-20mA,  4-20mA, 0 -5vdc
  • Certificate Of Calibration (Per Temperature Point)

Good performance and reliability are what you expect when you buy precision products from The Pyrometer Instrument Company, Inc.. The Pyrofiber® Laboratory infrared thermometer comes complete with a one year factory warranty.  For complete details visit our Product Warranty Page.
 