Filament Lamp, ribbon filament
tungsten
• Optical
Pyrometer temperature calibration
source
Temperature Range: 1420°F - 4200°F
(800°C - 2300°C)
Accuracy: ±5°F.
Source Type: Certified
Filament Tungsten Strip Lamp
Certificate of Calibration to NIST
|
|
Calibration Strip Lamp Datasheet
(60 KB)
|
Currently Out of Stock |
Classification -
filament lamp, ribbon filament
tungsten, optical pyrometer temperature calibration.

Optical Tungsten Ribbon Filament Strip Lamps are used to calibrate Optical pyrometers. The Lamp is built with a sapphire window spectral range that eliminates reflection
and an excellent thermal radiation source. The whisker in the ribbon filament allows for improved linearity. Pyrometer
supplies a certificate of calibration, which
provides the observed amperes data of specific
temperature points for the end user.


|
Window / Spectral Range: |
Sapphire 0.3 - 3 microns |
|
Bulb Specifications: |
74.5
mm Diameter |
| |
240
mm Height |
| |
130
mm Height to Element Center |
| |
E40
/ 45 Cap, uses mogul type socket |
| |
2.6
x 20 mm Ribbon Vertical element dim. |
| |
20-32a current rating |
| |
8-10.5
voltage rating
Note: All measurements are taken at the Whisker
Position on the element.
The Whisker is located in the nominal
center position. |
When Ordering Specify: Fahrenheit or Centigrade
temperature range, with or without magnifying.
|
STRIP LAMP AGED |
AGED and CALIBRATED with
Certificate of Calibration |
|
Model STL-L |
Low Range Lamp: 1400°F - 3400°F
(800°C - 1900°C) |
|
Model STL-H |
High Range Lamp: 1400°F - 4200°F
(800°C - 2300°C) |
|
Model SCLH |
Mounting Socket, Porcelain Lamp
Holder Base (2.56" x 2.13") |
LAMP CALIBRATION INFORMATION
- Data for the lamp has been accomplished by comparison to standards whose accuracy are traceable to national standards maintained by the National Institute of Standards & Technology.
- In accordance with lamp specifications, all brightness temperatures are measured at a wavelength of 0.655 microns using a magnification lens. The maximum uncertainties of the values at 1800°F and 2000°F correspond to about ±5°F. At higher and lower temperatures the maximum uncertainties are larger, increasing to about ±10°F at 1400°F and 3400°F.
- These supplied values apply when the lamp is operated vertically with its base down. The optical alignment must be made horizontally and perpendicular to the filament. The sighting must be made on the center of the filament across from the whisker line mark. In order to avoid errors in temperature readings due to excessive extraneous light being reflected from the filament, observations up to 1000°C should be made with a hood or shield covering the lamp and sighting through a hole in the shield. For temperatures above 1000°C, stray light will not affect temperature readings and the shield should be removed to permit dissipation of the heat from the lamp at elevated temperatures.

Good performance and reliability are
what you expect when you buy precision products from
The Pyrometer Instrument Company, Inc.. The Optical
Tungsten Ribbon Filament Strip Lamp comes complete with a one year factory warranty. For complete details visit our Product Warranty Page.
|