Start page
Media library
watch list
Contact
Search
Log in
Shopping cart
Search results
Log in
User name/email
Password
Log in
Menu
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Pyrometers
Pyrometers
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
Application solutions
Contact
Contact
Support
FAQs
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Furnace applications
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
IO-Link
Measuring system PA 29-K001
Article description
Measuring system consisting of:
Pyrometer CellaTemp PA 29 AF 21
Mounting combinations PA 20-071
Quartz protective window 70146
Special features:
Pyrometer with focusable optics in a stainless steel housing, for the measurement of metals in case of low temperatures, with special blocking filter for blocking interfering radiation
broadband anti-reflective precision lens
2 analogue outputs, 2 switching outputs, USB and RS 485
Sighting aid: laser pilot light
Flexibly adjustable mounting device
Measuring system PA 29-K001
You can request this article from us
Quantity:
Request item
Version
CellaTemp PA 29-K001
Measuring range
180 - 1200 °C
Focal range
0,4 m - ∞
Shape of the measuring field
round
Distance ratio
60 : 1
Objective
PZ 20.01
Measuring principle
one-color
Sighting option
Laser pilot light
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Measuring system PA 29-K001
Technical Data
Measurement parameters
Measuring range
150 - 2500 °C in Teilbereichen
Sensor
Photodiode
Spectral range
1.8 - 2.2 µm
Response time t98
Measuring range 150 - 800 °C:
≤ 50 ms (T > 150 °C)
≤ 15 ms (T > 200 °C)
≤ 2 ms (T > 350 °C)
Measuring range 180 - 1,200 °C:
≤ 75 ms (T > 180 °C)
≤ 35 ms (T > 200 °C)
≤ 5 ms (T > 300 °C)
≤ 2 ms (T > 600 °C)
Measuring range 250 - 2,000 °C:
≤ 50 ms (T > 250 °C)
≤ 2 ms (T > 750 °C)
Messbereich 350 - 2500 °C:
≤ 50 ms (T >350 °C)
≤ 2 ms (T > 900 °C)
Measurement uncertainty
Measuring range 150 - 800 °C and 180 - 1,200 °C:
0.75 % of temp. reading [°C] min. 5 K
Messbereich 250 - 2000 °C und 350 - 2500 °C:
0.5 % of temp. reading [°C] min. 4 K
Repeatability
1 K
Temperature coefficient
0.25 K/K (T < 500 °C)
0.05 %/K (T > 500 °C)
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
Measuring range 150 - 800 °C and 180 - 1,200 °C:
0.1 K < 200 °C
1 K ≥ 200 °C
Messbereich 250 - 2000 °C und 350 - 2500 °C:
1 K
Optical variants
Objective lenses
Measuring range 150 - 800 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Measuring range 180 - 1,200 °C:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Messbereich 250 - 2000 °C und 350 - 2500 °C:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Analog input
0 - 10 V
Switching output
2 x Open Collector 24 V DC, ≤ 30 mA
Switching input
2 x to 24 V
Interface
USB
Interface
RS 485
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
video camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
video camera
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 8-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Measuring range
Measured variable and scaling of analogue input and output signals
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Compensation of background radiation
Limit values and operating mode of the alarm contacts
Parameters of the ATD function (optional)
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°F
additionally for pyrometer with camera:
TBC funktion
White balance
Functions
Overtemperature signal
if the internal temperature exceeds 80 °C, the analog output shows a value > 20.5 mA
Service function
Simulation of a measured value or a current signal
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Measuring system PA 29-K001
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Measuring system PA 29-K001
Downloads
Brochure CellaTemp PA
Manual CellaTemp PA 1x 2x 3x
Drawing PA 29-K001
EAC Deklaration PK-PA-PT
X
Measuring system PA 29-K001
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Accessories for interfaces SU 02 AF 1
Add to Cart
Adapter flange PZ 20/H
Add to Cart
Adapter ring PZ 20/E
Add to Cart
Air purge PZ 20/A AF 1
Add to Cart
Aluminum compact hose PB 08/L
Add to Cart
Ball and socket mount PZ 10/H
Add to Cart
Cable VK 01/Y AF 3
Add to Cart
Cable VK 02/A AF 1
Add to Cart
Cable VK 02/A AF 2
Add to Cart
Cable VK 02/A AF 3
Add to Cart
Cable VK 02/B
Add to Cart
Cable VK 02/C AF 1
Add to Cart
Cable VK 02/C AF 2
Add to Cart
Clamping collar PZ 20/L AF 2
Add to Cart
Clamping collar PZ 20/N AF 2
Add to Cart
Close-up optics PZ 20.03
Add to Cart
Cooling jacket PA 20/B AF 1
Add to Cart
Cooling jacket PA 20/M AF 1
Add to Cart
Cooling jacket PA 20/M AF 2
Add to Cart
Cooling jacket PA 20/M AF 3
Add to Cart
Cooling jacket PA 20/M AF 4
Add to Cart
Deflection mirror PA 20/E AF 1
Add to Cart
Deflection mirror PA 20/E AF 2
Add to Cart
Digital display DA 230A
Add to Cart
Dust stop PZ 10/S
Add to Cart
Dust stop PZ 10/T
Add to Cart
Emissivity switching box VK 30.07
Add to Cart
Fan PB 08/F AF 3
Add to Cart
Flange PB 08/R AF 1
Add to Cart
Flange PB 08/R AF 2
Add to Cart
Flange PK 20/F-70
Add to Cart
Flange tube PB 08/M AF1
Add to Cart
Holder PB 08/K AF 2
Add to Cart
Holder PB 08/Q AF 1
Add to Cart
Hose clamp
On Request
Hose clamp 0
Add to Cart
Illumination ring PZ 10/P
Add to Cart
Industrial hose GP 40
Add to Cart
Interface converter SU 04 AF 1
Add to Cart
Intermediate tube PZ 20/C
Add to Cart
Intermediate tube PZ 20/J
Add to Cart
Intermediate tube PZ 40/C
Add to Cart
Junction box VK 30.02
Add to Cart
Lens PZ 20.08
Add to Cart
Monitor system 0
Add to Cart
Mounting bracket PA 11/K
Add to Cart
Mounting bracket PA 11/U
Add to Cart
Mounting bracket PZ 20/U AF 2
Add to Cart
Mounting combinations PA 20-059
On Request
Mounting combinations PA 20-060
On Request
Mounting combinations PA 20-064
On Request
Mounting combinations PA 20-071
On Request
Mounting combinations PA 20-073
On Request
Mounting combinations PA 20-077
On Request
Mounting combinations PA 20-080
On Request
Mounting combinations PA 20-081
On Request
Mounting combinations PA 20-091
On Request
Mounting combinations PA 20-098
On Request
Mounting combinations PA 20-099
On Request
Mounting combinations PA 20-100
On Request
Mounting combinations PA 20-101
On Request
Mounting combinations PA 20-102
On Request
Mounting combinations PA 20-103
On Request
Mounting combinations PA 20-104
On Request
Mounting combinations PA 20-107
On Request
Mounting combinations PA 20-112
On Request
Mounting combinations PA 20-117
On Request
Mounting combinations PA 20-122
On Request
Mounting combinations PA 83-002
On Request
Mounting combinations PA 83-007
On Request
Mounting combinations PA 83-010
On Request
Mounting combinations PA 83-011
On Request
Mounting flange PZ 20/F-120
Add to Cart
Mounting flange PZ 20/F-120 DN50
Add to Cart
Mounting flange PZ 20/F-130
Add to Cart
Mounting flange PZ 20/F-145
Add to Cart
Mounting flange PZ 20/F-160
Add to Cart
Mounting flange PZ 20/F-50
Add to Cart
Mounting flange PZ 40/D
Add to Cart
Mounting flange PZ 40/N-130 AF 1
Add to Cart
Opto-coupling SU 07 AF 1
Add to Cart
Protective cap PA 20/K
Add to Cart
Protective enclosure PA 40/B AF 1
Add to Cart
Protective enclosure PA 40/M AF 1
Add to Cart
Protective enclosure PA 40/M AF 2
Add to Cart
Quartz protective window 70146
Add to Cart
Quartz window PA 20/I
Add to Cart
Quartz window with hinge PZ 20/I AF 1
Add to Cart
Quick coupling PA 20/C
Add to Cart
Quick coupling PA 20/D
Add to Cart
Radiation protection shield PA 20/S AF 1
Add to Cart
Servo mirror PZ 20/X AF 5
Add to Cart
Servo mirror PZ 20/X AF 6
Add to Cart
Shaft nut 0
Add to Cart
Sighting tube PA 20/R AF 1
Add to Cart
Spherical flange PB 08/I
Add to Cart
Spherical flange PB 08/I AF 2
Add to Cart
Standard optics PZ 20.01
Add to Cart
Tele-optics PZ 20.06
Add to Cart
Thermal insulating tube PZ 20/K
Add to Cart
Threaded ring 0
Add to Cart
Toggle adapter PZ 40/G
Add to Cart
Video cable VK 02/F AF 1
Add to Cart
Video cable VK 02/F AF 2
Add to Cart
Video cable VK 02/F AF 3
Add to Cart
Wide-angle optics PZ 20.05
Add to Cart
Measuring system PA 29-K001
IO-Link IODD
Measuring system PA 29-K001
IO-Link Manufacturer declaration
Measuring system PA 29-K001
Measurement field calculator
Pyrometer
PA 29 AF 21
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
6.67 mm
Measuring distance
Measuring field diameter
0.00 mm
18.00 mm
16.00 mm
17.55 mm
32.00 mm
17.09 mm
48.00 mm
16.64 mm
64.00 mm
16.19 mm
80.00 mm
15.73 mm
96.00 mm
15.28 mm
112.00 mm
14.83 mm
128.00 mm
14.37 mm
144.00 mm
13.92 mm
160.00 mm
13.47 mm
176.00 mm
13.01 mm
192.00 mm
12.56 mm
208.00 mm
12.11 mm
224.00 mm
11.65 mm
240.00 mm
11.20 mm
256.00 mm
10.75 mm
272.00 mm
10.29 mm
288.00 mm
9.84 mm
304.00 mm
9.39 mm
320.00 mm
8.93 mm
336.00 mm
8.48 mm
352.00 mm
8.03 mm
368.00 mm
7.57 mm
384.00 mm
7.12 mm
400.00 mm
6.67 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2025 –
Internetagentur
– Wrocklage Werbewerkstatt