Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Measuring system PK 11-K002
Article description
Measuring system consisting of:
Mounting combinations PK 01-007
Cable VK 02/L AF 1
Special features:
Compact infrared thermometer with bright LED display and control panel -- broadband anti-reflective precision lens -- analogue output and IO link interface -- Mounting fitting with flow-optimized air flow to avoid contaminations with minimal air consumption -- Flexibly adjustable holding device
Measuring system PK 11-K002
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PK 11-K002
Measuring range
0 - 1000 °C
Measuring field
33 mm
Focal range
0,9 m
Shape of the measuring field
round
Measuring principle
one-color
Technical Data
Downloads
Measurement field calculator
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Measuring system PK 11-K002
Technical Data
Measurement parameters
Measuring range
0 - 1000 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t90
≤ 60 ms
Measurement uncertainty
0.75 % of temp. reading [°C] plus 2.0 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output
0,1 K + 0,0005 % der eingestellten Messspanne
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x PNP Open Collector 24 V DC, 2 x 150 mA max.
Interface
IO-Link V1.1.3
Power supply
18-30 V DC
Current consumption
≤ 50 mA at 24 V DC
Equipment
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin (A coded)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 185 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Transsmissionsgrad der Schutzscheibe
Damping time constant
Holding time of the peak picker
Betriebsart, Quelle und Schaltpunkt, Ein- und Ausschaltverzögerung der Schaltkontakte
Stützstellen der Nachlinearisierung
Vitalitätsindikator
Serviceparameter
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Prozesswertanzeige
Simulation of temperature
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Test function
via pushbutton or test input
Service function
Simulation of a measured value
Diagnostic function
Reverse polarity, overload and incorrect supply voltage indication
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrared thermometer CellaTemp PK
Operating manual (short)
2 fastening nuts
Measuring system PK 11-K002
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Measuring system PK 11-K002
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaTemp PKx IO-Link
Quick guide CellaTemp PKxx IO-Link
Drawing PK 11-K002
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Measuring system PK 11-K002
Accessories
Wir haben leider kein passendes Zubehör gefunden.
Measuring system PK 11-K002
IO-Link IODD
Measuring system PK 11-K002
IO-Link Manufacturer declaration
Measuring system PK 11-K002
Measurement field calculator
Pyrometer
PK 11 AF 2
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
72
144
216
288
360
432
504
576
648
720
792
864
33.00 mm
Measuring distance
Measuring field diameter
0.00 mm
16.50 mm
36.00 mm
17.16 mm
72.00 mm
17.82 mm
108.00 mm
18.48 mm
144.00 mm
19.14 mm
180.00 mm
19.80 mm
216.00 mm
20.46 mm
252.00 mm
21.12 mm
288.00 mm
21.78 mm
324.00 mm
22.44 mm
360.00 mm
23.10 mm
396.00 mm
23.76 mm
432.00 mm
24.42 mm
468.00 mm
25.08 mm
504.00 mm
25.74 mm
540.00 mm
26.40 mm
576.00 mm
27.06 mm
612.00 mm
27.72 mm
648.00 mm
28.38 mm
684.00 mm
29.04 mm
720.00 mm
29.70 mm
756.00 mm
30.36 mm
792.00 mm
31.02 mm
828.00 mm
31.68 mm
864.00 mm
32.34 mm
900.00 mm
33.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt