Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Measuring system PKF 66-K001
Article description
Measuring system consisting of:
Pyrometer CellaTemp PKF 66 AF 1
Mounting combinations PK 01-007
Mounting bracket set PS 11/U
Cable VK 02/L AF 1
Special features:
Two-colour infrared thermometer with fibre optics cable and optical measuring head -- Measuring head can be used without cooling in ambient temperatures up to 250 °C -- Analogue output and IO-Link interface -- Mounting fitting with flow-optimized air flow to avoid contaminations with minimal air consumption -- Flexibly adjustable holding device
Measuring system PKF 66-K001
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PKF 66-K001
Measuring range
700 - 1800 °C
Focal range
0,2 m - ∞
Shape of the measuring field
round
Distance ratio
190 : 1
Measuring principle
two-color
Sighting option
Laser pilot light
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Measuring system PKF 66-K001
Technical Data
Measurement parameters
Measuring range
700 - 1800 °C
Sensor
Double photodiode
Spectral range
0.95 / 1.05 µm
Response time t90
≤ 10 ms (T > 800 °C)
Measurement uncertainty
1 % vom Messwert [°C] zzgl. 3,0 K
Repeatability
2 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Measuring heads
AF 1: PA 41.01 (M30): focusing 0.2 m - ∞
AF 2: PKS 21.01 (M30): focusing 1.08 m
AF 3: PA 41.05 (M16): focusing 0.12 m - ∞
AF 4: PZ 41.18 (M16): focusing 0.033 - 0.045 m
AF 5: PA 41.03 (M30): focusing 1.8 m (sealed)
Electrical parameters
Analog output
0(4)Â - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
Equipment
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin (A coded)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 210 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Transmittance
Damping time constant
Holding time of the peak picker
Operating mode and switching points of the switching contacts
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Simulation of temperature
Threshold value of the DTD function
Measuring channel two-colour, one-colour 1 and one-colour 2
Warning and cut-off threshold of the contamination monitoring
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value
DTD (Discontinuous Temperature Detection) function
Automatic temperature detection at discontinuous processes
Diagnostic function
Reverse polarity, overload and incorrect supply voltage indication
Reverse polarity protection
M12 screw connection 5-pin (A coded)
Scope of delivery
Scope of delivery
Infrared thermometer CellaTemp PKF
Measuring head
Operating manual (short)
2 fastening nuts
* The fibre optic cable must be ordered separately.
Measuring system PKF 66-K001
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Measuring system PKF 66-K001
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaTemp PKx IO-Link
Quick guide CellaTemp PKxx IO-Link
Drawing PKF 66-K001
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Measuring system PKF 66-K001
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bayonet coupling PS 11/N AF 4
On Request
Bayonet coupling PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Dust stop ZA 01/C
On Request
Fiber optic cable LWL (10HT) 200µm
On Request
Fiber optic cable LWL (20HT) 200µm
On Request
Fiber optic cable LWL (25HT) 200µm
On Request
Fiber optic cable LWL (2HT) 200µm
On Request
Fiber optic cable LWL (5HT) 200µm
On Request
Fiber optic measuring head PA 41.01
On Request
Fiber optic measuring head PA 41.02
On Request
Fiber optic measuring head PA 41.03
On Request
Fiber optic measuring head PKS 21.01
On Request
Fiber optic measuring head PZ 41.18
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
IO-Link software SW 50 AF 1
Laser pointer PK 01/E AF 2
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting combinations PK 01-006
On Request
Mounting combinations PK 01-007
On Request
Mounting combinations PK 01-011
On Request
Mounting combinations PK 01-014
On Request
Mounting combinations PK 21-001
On Request
Mounting combinations PK 21-002
On Request
Mounting combinations PK 21-004
On Request
Mounting combinations PK 21-005
On Request
Mounting combinations PK 21-006
On Request
Mounting combinations PK 21-007
On Request
Mounting combinations PK 21-008
On Request
Mounting combinations PK 21-009
On Request
Mounting combinations PK 21-012
On Request
Mounting flange Flansch DN 50 - R1.1/4"
On Request
Plate ZA 01/S
On Request
Plate ZA 01/W
On Request
Quartz window PS 01/I AF 2
On Request
Sapphire protective window PS 15/I AF 1
On Request
Supplementary lens PK 21/E AF 2
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Tube cap ZA 01/A
On Request
Measuring system PKF 66-K001
IO-Link IODD
Measuring system PKF 66-K001
IO-Link Manufacturer declaration
Measuring system PKF 66-K001
Measurement field calculator
Pyrometer
PKF 66 AF 1
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
8
16
24
32
40
48
56
64
72
80
88
96
104
112
120
128
136
144
152
160
168
176
184
192
200
1.05 mm
Measuring distance
Measuring field diameter
0.00 mm
23.40 mm
8.00 mm
22.51 mm
16.00 mm
21.61 mm
24.00 mm
20.72 mm
32.00 mm
19.82 mm
40.00 mm
18.93 mm
48.00 mm
18.04 mm
56.00 mm
17.14 mm
64.00 mm
16.25 mm
72.00 mm
15.35 mm
80.00 mm
14.46 mm
88.00 mm
13.57 mm
96.00 mm
12.67 mm
104.00 mm
11.78 mm
112.00 mm
10.89 mm
120.00 mm
9.99 mm
128.00 mm
9.10 mm
136.00 mm
8.20 mm
144.00 mm
7.31 mm
152.00 mm
6.42 mm
160.00 mm
5.52 mm
168.00 mm
4.63 mm
176.00 mm
3.73 mm
184.00 mm
2.84 mm
192.00 mm
1.95 mm
200.00 mm
1.05 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt