Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Measuring system PX 18-K002
Description
Measuring system consisting of:
Pyrometer CellaTemp PX 18 AF 1
Mounting PA 15-008
Special features:
Pyrometer with focusable optics in a stainless steel housing
for the measurement of hot CO2 gases in combustion chambers in combustion processes
broadband anti-reflective precision lens
1 analogue output
2 switching outputs
IO-Link Sighting aid: video camera Mounting fitting with cooling fitting and air purge for industrial use
Measuring system PX 18-K002
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PX 18-K002
Measuring range
500 - 2500 °C
Focal distance
0,8 m - ∞
Shape of the measurement area
round
Distance ratio
70 : 1
Objective
PZ 15.03
Measuring principle
one-colour
Sighting option
Video camera
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Measuring system PX 18-K002
Technical Data
Measurement parameters
Measuring range
500 - 2500 °C
Sensor
Thermopile
Spectral range
CO range
Response time t98
≤ 100 ms
Measurement uncertainty
0.75 % of temp. reading [°C], min. 3 K
Repeatability
2 K
Temperature coefficient
0.04 %/K
Resolution current output
0.2 K + 0.03 % of selected range
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Lenses
Standard-Objektiv PZ 15.03: Fokussierung 0,8 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA bei 24 V DC
Camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Features
Sighting option
Through-the-lens-sighting
Display
4-digit LED display red, digit-height 8 mm
Status display
4 x LED
Control elements
3 buttons
General parameters
Connection
M12 thread 5-pin connection
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing
Stainless steel V2A (1.4305)
Protection class
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analog output
Smoothing filter
Memory operation mode
Hold time of the memory
Emissivity
Transmittance
Limits and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
in addition, for model with camera:
TBC function
White balance
Measuring point number
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
Manual (short)
Measuring system PX 18-K002
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Measuring system PX 18-K002
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Manual CellaTemp PX 1x 2x 3x
Drawing PX 18-K002
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Measuring system PX 18-K002
Accessories
Software
Electrical accessories
Mechanical accessories
Adapter flange PB 08/J AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminium compact hose PB 08/L
On Request
Ball and socket mounting PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Digital display DA 570
On Request
Emissivity switching box VK 30.07
On Request
Fan PB 08/F AF 3
On Request
Fan PB 08/F AF 4
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange PZ 20/F-120
On Request
Flange PZ 20/F-120 DN50
On Request
Flange PZ 20/F-130
On Request
Flange PZ 20/F-145
On Request
Flange PZ 20/F-160
On Request
Flange PZ 20/F-50
On Request
Flange PZ 40/D
On Request
Flange PZ 40/N-130 AF 1
On Request
Flange PZ 40/N-130 AF 2
On Request
Flange tube PB 08/M AF1
On Request
Flange ZA 10/F-160
On Request
Holding device PB 08/K AF 2
On Request
Holding device PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Interface isolator SU 07 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link Software SW 50 AF 1
Junction box VA 20.01
On Request
Junction box VK 30.04
On Request
Junction box VK 30.05
On Request
Material selector switch VK 30.01
On Request
Mounting angle PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting socket PZ 20/G AF 1
On Request
Oscillating mirror PZ 20/X AF 5
On Request
Oscillating mirror PZ 20/X AF 6
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Spherical flange PB 08/I AF 3
On Request
Spherical flange PB 08/I AF 4
On Request
Steckernetzteil E2EFSW3 12W-24V
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Universal-Regler URE 422 RA
On Request
Video encoder SU 08 AF 1
On Request
Videokabel VK 02/F AF 1
On Request
Videokabel VK 02/F AF 2
On Request
Videokabel VK 02/F AF 3
On Request
Measuring system PX 18-K002
IO-Link IODD
Measuring system PX 18-K002
IO-Link Manufacturer explanation
Measuring system PX 18-K002
Field-of-view calculator
Pyrometer
PX 18 AF 1
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
64
128
192
256
320
384
448
512
576
640
704
768
11.43 mm
Measuring distance
Spot diameter
0.00 mm
24.00 mm
32.00 mm
23.50 mm
64.00 mm
22.99 mm
96.00 mm
22.49 mm
128.00 mm
21.99 mm
160.00 mm
21.49 mm
192.00 mm
20.98 mm
224.00 mm
20.48 mm
256.00 mm
19.98 mm
288.00 mm
19.47 mm
320.00 mm
18.97 mm
352.00 mm
18.47 mm
384.00 mm
17.97 mm
416.00 mm
17.46 mm
448.00 mm
16.96 mm
480.00 mm
16.46 mm
512.00 mm
15.95 mm
544.00 mm
15.45 mm
576.00 mm
14.95 mm
608.00 mm
14.45 mm
640.00 mm
13.94 mm
672.00 mm
13.44 mm
704.00 mm
12.94 mm
736.00 mm
12.43 mm
768.00 mm
11.93 mm
800.00 mm
11.43 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2023 –
Internetagentur
– Wrocklage Werbewerkstatt