Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaCast PA 83
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaCast PA 83
Article description
The CellaCast PA 83 was specially developed for measuring the temperature of liquid metals on automatic casting machines for plug and ladle casting. When measuring on an automatic casting machine, the position of the pouring stream can change depending on the outlet or the tilt angle of the ladle. The special feature of the CellaCast PA 83 is the rectangular measuring field. As long as the pouring stream remains within the measuring field, a reliable measured value is determined.
Special features:
Measuring range 650 to 1
700 °C -- wear-free and maintenance-free measuring system for temperature measurement of the pouring stream on automatic casting machines -- lens with rectangular measuring field for reliable measurement even with fluctuating position of the pouring stream -- ATD function for automatic recording and monitoring of the temperature for each casting -- two-colour measuring method for interference-free measurement in dust and vapour -- through-the-lens sighting or video camera for correct alignment and monitoring of the measuring field -- very large and bright LED display
Pyrometer CellaCast PA 83
Properties
Version
Measuring range
650 - 1700 °C
650 - 1700 °C
750 - 2400 °C
Focal range
0,2 m - ∞
0,2 m - ∞
0,3 m - ∞
0,4 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Video camera
Your selection will impact other settings.
Version
AF 1
AF 3
AF 10
AF 11
AF 13
Sight
Through-the-lens sighting
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaCast PA 83 AF 1
Version
CellaCast PA 83 AF 3
Version
CellaCast PA 83 AF 10
Version
CellaCast PA 83 AF 11
Version
CellaCast PA 83 AF 13
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Measuring range
750 - 2400 °C
Measuring range
650 - 1700 °C
Focal range
0,4 m - ∞
Focal range
1,2 m - ∞
Focal range
0,2 m - ∞
Focal range
0,2 m - ∞
Focal range
0,3 m - ∞
Shape of the measuring field
rectangular
Distance ratio
45:1 / 230:1
Distance ratio
75:1 / 375:1
Distance ratio
10:1 / 55:1
Distance ratio
11:1 / 85:1
Distance ratio
30:1 / 150:1
Objective
PZ 20.01
Objective
PZ 20.06
Objective
PZ 20.05
Objective
PZ 20.05
Objective
PZ 20.08
Measuring principle
two-color
Sighting option
Through-the-lens sighting
Sighting option
Video camera
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaCast PA 83
Technical Data
Measurement parameters
Measuring range
650 - 2,400 °C in sub-ranges
Sensor
Double photodiode
Spectral range
0.95 / 1.05 µm
Response time t98
Measuring range 650 - 1,700 °C:
≤ 10 ms (T > 750 °C)
Measuring range 750 - 2,400 °C:
≤ 10 ms (T > 950 °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Objective lenses
both measuring ranges:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens I PZ 20.06: focusing 1.2 m - ∞
Telephoto lens II PA 20.06: focusing 0.6 m - ∞
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
additionally for measuring range 750 - 2,400 °C:
Macro objective lens PA 40.01: focusing 0.086 m - 0.115 m
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Analog input
0 - 10 V
Switching output
2 x Open Collector 24 V DC, ≤ 30 mA
Switching input
2 x to 24 V
Interface
USB
Interface
RS 485
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
video camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
video camera
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 8-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Measuring range
Measured variable and scaling of analogue input and output signals
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Compensation of background radiation
Limit values and operating mode of the alarm contacts
Parameters of the ATD function
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°F
Measuring channel two-colour, one-colour 1 and one-colour 2
Threshold value of the contamination monitoring
additionally for pyrometer with camera:
TBC funktion
White balance
Functions
Overtemperature signal
if the internal temperature exceeds 80 °C, the analog output shows a value > 20.5 mA
Service function
Simulation of a measured value or a current signal
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Pyrometer CellaCast PA 83
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCast PA 83
Downloads
Brochure CellaCast PA83 PT183
Brochure CellaView
Application report CellaCast
Manual CellaCast PA 8x
Quick guide CellaCast PA 8x
Declaration of conformity Declaration of Conformity PAxx
UKCA Declaration of Conformity PAxx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaCast PA 83
Accessories
Electrical accessories
Mechanical accessories
Mounting solutions
Accessories for interfaces SU 02 AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Dust stop PZ 10/T
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
Junction box VK 30.02
On Request
Junction box VK 30.07
On Request
LCD monitor 0
On Request
Monitor system 0
On Request
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PA 20-071
On Request
Mounting combinations PA 83-001
On Request
Mounting combinations PA 83-002
On Request
Mounting combinations PA 83-003
On Request
Mounting combinations PA 83-004
On Request
Mounting combinations PA 83-005
On Request
Mounting combinations PA 83-006
On Request
Mounting combinations PA 83-007
On Request
Mounting combinations PA 83-008
On Request
Mounting combinations PA 83-009
On Request
Mounting combinations PA 83-010
On Request
Mounting combinations PA 83-011
On Request
Mounting combinations PA 83-013
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quartz window PA 20/I
On Request
Quartz window with hinge PZ 20/I AF 1
On Request
Quick coupling PA 20/C
On Request
Quick coupling PA 20/D
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Pyrometer CellaCast PA 83
IO-Link IODD
Pyrometer CellaCast PA 83
IO-Link Manufacturer declaration
Pyrometer CellaCast PA 83
Measurement field calculator
Pyrometer
PA 83 AF 1
(0,4 m - ∞)
PA 83 AF 10
(0,2 m - ∞)
PA 83 AF 11
(0,2 m - ∞)
PA 83 AF 13
(0,3 m - ∞)
PA 83 AF 3
(1,2 m - ∞)
PA 83 AF 1
(0,4 m - ∞)
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
8.89 x
1.74 mm
Measuring distance
Messfeldbreite
Messfeldhöhe
0.00 mm
19.00 mm
19.00 mm
16.00 mm
18.60 mm
18.31 mm
32.00 mm
18.19 mm
17.62 mm
48.00 mm
17.79 mm
16.93 mm
64.00 mm
17.38 mm
16.24 mm
80.00 mm
16.98 mm
15.55 mm
96.00 mm
16.57 mm
14.86 mm
112.00 mm
16.17 mm
14.17 mm
128.00 mm
15.76 mm
13.48 mm
144.00 mm
15.36 mm
12.79 mm
160.00 mm
14.96 mm
12.10 mm
176.00 mm
14.55 mm
11.41 mm
192.00 mm
14.15 mm
10.71 mm
208.00 mm
13.74 mm
10.02 mm
224.00 mm
13.34 mm
9.33 mm
240.00 mm
12.93 mm
8.64 mm
256.00 mm
12.53 mm
7.95 mm
272.00 mm
12.12 mm
7.26 mm
288.00 mm
11.72 mm
6.57 mm
304.00 mm
11.32 mm
5.88 mm
320.00 mm
10.91 mm
5.19 mm
336.00 mm
10.51 mm
4.50 mm
352.00 mm
10.10 mm
3.81 mm
368.00 mm
9.70 mm
3.12 mm
384.00 mm
9.29 mm
2.43 mm
400.00 mm
8.89 mm
1.74 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt