Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaCast PT 183
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaCast PT 183
Article description
The CellaCast PT 183 was specially developed for mobile temperature measurement of liquid metals. It is used to check the temperature at the automatic casting machine during plugging or ladle casting directly when filling the moulds. This is complicated by the fact that the position of the pouring stream can change depending on the outlet or the tilt angle of the ladle. The special feature of the CellaCast PT 183 is the rectangular measuring field. As long as the pouring stream remains within the measuring field, a reliable measured value is determined. Furthermore, the CellaCast PT 183 can be used to determine the temperature when transferring the metal from the melting or holding furnace into the transport ladle or casting ladle.
Special features:
Non-contact and wear-free temperature measurement of the pouring stream from a safe distance -- measuring range 650 - 1
700 °C -- rectangular measuring field for reliable measurement even with fluctuating position of the pouring stream -- filtering of the correct infrared radiation of the slag-free and oxide-free melt -- ATD function for fully automatic measured value acquisition -- two-colour measurement for interference-free measurement in dust and vapour -- parallax-free through-the-lens sighting with dioptric compensation -- traffic light display in the through-the-lens sighting to indicate the optimum measuring distance
Pyrometer CellaCast PT 183
Properties
Version
Measuring range
650 - 1700 °C
650 - 1700 °C
Focal range
0,3 m - ∞
0,3 m - ∞
0,4 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Your selection will impact other settings.
Version
AF 1
AF 3
AF 13
Sight
Through-the-lens sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaCast PT 183 AF 1
Version
CellaCast PT 183 AF 3
Version
CellaCast PT 183 AF 13
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Focal range
0,4 m - ∞
Focal range
1,2 m - ∞
Focal range
0,3 m - ∞
Shape of the measuring field
rectangular
Distance ratio
45:1 / 230:1
Distance ratio
75:1 / 375:1
Distance ratio
30:1 /150:1
Objective
PZ 20.01
Objective
PZ 20.06
Objective
PZ 20.08
Measuring principle
two-color
Sighting option
Through-the-lens sighting
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaCast PT 183
Technical Data
Measurement parameters
Measuring range
650 - 2,400 °C in sub-ranges
Sensor
Double photodiode
Spectral range
0.95 / 1.05 µm
Response time t98
Measuring range 650 - 1,700 °C:
≤ 10 ms (T > 750 °C)
Measuring range 750 - 2,400 °C:
≤ 10 ms (T > 950 °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Objective lenses
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Electrical parameters
Interface
USB
Power supply
Built-in rechargeable battery
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Equipment
Sighting option
through-the-lens sighting
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED external
3 x LED internal
Operator controls
3 pushbuttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing material
Aluminum
Type of protection
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of background radiation
Smoothing filter
Operating mode and holding time of the measured value memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Measuring channel two-colour - one-colour
Threshold value of the signal monitoring
Functions
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Pyrometer CellaCast PT 183
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCast PT 183
Downloads
Brochure CellaCast PA83 PT183
Brochure CellaView
Application report CellaCast
Manual CellaPort PT 18x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaCast PT 183
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
carrying case PT 110/A
On Request
Floor stand PT 50/B AF 2
On Request
Lens cap 94246
On Request
Plug-in power supply NN090P080PGS
On Request
Quartz protective window 70146
On Request
Pyrometer CellaCast PT 183
IO-Link IODD
Pyrometer CellaCast PT 183
IO-Link Manufacturer declaration
Pyrometer CellaCast PT 183
Measurement field calculator
Pyrometer
PT 183 AF 1
(0,4 m - ∞)
PT 183 AF 13
(0,3 m - ∞)
PT 183 AF 3
(1,2 m - ∞)
PT 183 AF 1
(0,4 m - ∞)
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
8.89 x
1.74 mm
Measuring distance
Messfeldbreite
Messfeldhöhe
0.00 mm
19.00 mm
19.00 mm
16.00 mm
18.60 mm
18.31 mm
32.00 mm
18.19 mm
17.62 mm
48.00 mm
17.79 mm
16.93 mm
64.00 mm
17.38 mm
16.24 mm
80.00 mm
16.98 mm
15.55 mm
96.00 mm
16.57 mm
14.86 mm
112.00 mm
16.17 mm
14.17 mm
128.00 mm
15.76 mm
13.48 mm
144.00 mm
15.36 mm
12.79 mm
160.00 mm
14.96 mm
12.10 mm
176.00 mm
14.55 mm
11.41 mm
192.00 mm
14.15 mm
10.71 mm
208.00 mm
13.74 mm
10.02 mm
224.00 mm
13.34 mm
9.33 mm
240.00 mm
12.93 mm
8.64 mm
256.00 mm
12.53 mm
7.95 mm
272.00 mm
12.12 mm
7.26 mm
288.00 mm
11.72 mm
6.57 mm
304.00 mm
11.32 mm
5.88 mm
320.00 mm
10.91 mm
5.19 mm
336.00 mm
10.51 mm
4.50 mm
352.00 mm
10.10 mm
3.81 mm
368.00 mm
9.70 mm
3.12 mm
384.00 mm
9.29 mm
2.43 mm
400.00 mm
8.89 mm
1.74 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt