Pyrometer
Product finder
Pyrometer CellaCast PX 81
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaCast PX 81
Description
The CellaCast PX 81 was specially developed for measuring the temperature of liquid metals in the casting channels of blast furnaces and cupola furnaces. Furthermore, the pyrometer is used when transferring the metal from the melting or holding furnace into the transport ladle or casting ladle. The two-colour pyrometer is equipped with a separate optical measuring head and a fibre optic cable. The fibre optic cable and measuring head are insensitive to interference from electromagnetic radiation and can be used in ambient temperatures up to 250 °C without cooling. The variant with separate optical measuring head has advantages especially in confined spaces.
Special features:
Measuring range 800 to 2,400 °C
wear-free and maintenance-free measuring system for temperature measurement in melting and holding furnaces as well as cupolas and blast furnaces
ATD function for filtering the temperature of the slag-free and oxide-free metal surface
two-colour measuring method for interference-free measurement in the presence of dust and vapour
high-resolution lens for reliable measurement even from a great distance
measuring head and fibre optic cable heat resistant up to 250 °C
Pyrometer CellaCast PX 81
Properties
Version
Measuring range
800 - 2400 °C
800 - 2400 °C
Focal distance
0,2 m - ∞
0,2 m - ∞
Sighting option
Laser pilot light
Laser pilot light
Your selection impact other settings.
Version
AF 11
Sighting option
Laser pilot light
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaCast PX 81 AF 11
Measuring range
800 - 2400 °C
Focal distance
0,2 m - ∞
Shape of the measurement area
round
Distance ratio
190 : 1
Measuring head
PA 41.01
Measuring principle
two-colour
Sighting option
Laser pilot light
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Pyrometer CellaCast PX 81
Technical Data
Measurement parameters
Measuring range
800 - 2400 °C
Sensor
Double photo diode
Spectral range
0.95 / 1.05 µm
Response time t98
≤ 20 ms (T > 950 °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected range
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Measuring heads
PA 41.01 (M30): Focusing 0.2 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA bei 24 V DC
Features
Sighting option
Laser pilot light
Display
4-digit LED display red, digit-height 8 mm
Status display
4 x LED
Control elements
3 buttons
General parameters
Connection
M12 thread 5-pin connection
Ambient temperature
Electronic: 0 - 65 °C
Measuring head: 250 °C
Storage temperature
-20 - +80 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Electronic: Ø 65 mm x 187 mm
Measuring head: depending on the type
Housing
Stainless steel V2A (1.4305)
Protection class
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analog output
Smoothing filter
Memory operation mode
Hold time of the memory
Emissivity
Transmittance
Limits and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
Measurement channel two-colour, single-colour 1 and single-colour 2
Threshold level of the contamination monitoring
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Measuring head
Manual (short)
* The fibre optic cable must be ordered separately.
Pyrometer CellaCast PX 81
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCast PX 81
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Manual CellaCast PX 8x
Quick guide CellaCast PX 8x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaCast PX 81
Accessories
Software
Electrical accessories
Mechanical accessories
Mountings
Adapter flange PB 08/J AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminium compact hose PB 08/L
On Request
Ball and socket mounting PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Digital display DA 570
On Request
Emissivity switching box VK 30.07
On Request
Fan PB 08/F AF 3
On Request
Fan PB 08/F AF 4
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange PZ 20/F-120
On Request
Flange PZ 20/F-120 DN50
On Request
Flange PZ 20/F-130
On Request
Flange PZ 20/F-145
On Request
Flange PZ 20/F-160
On Request
Flange PZ 20/F-50
On Request
Flange PZ 40/D
On Request
Flange PZ 40/N-130 AF 1
On Request
Flange PZ 40/N-130 AF 2
On Request
Flange tube PB 08/M AF1
On Request
Flange ZA 10/F-160
On Request
Holding device PB 08/K AF 2
On Request
Holding device PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Interface isolator SU 07 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link Software SW 50 AF 1
Junction box VA 20.01
On Request
Junction box VK 30.04
On Request
Junction box VK 30.05
On Request
Material selector switch VK 30.01
On Request
Mounting angle PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting PZ 41-003
On Request
Mounting socket PZ 20/G AF 1
On Request
Oscillating mirror PZ 20/X AF 5
On Request
Oscillating mirror PZ 20/X AF 6
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Spherical flange PB 08/I AF 3
On Request
Spherical flange PB 08/I AF 4
On Request
Steckernetzteil E2EFSW3 12W-24V
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Universal-Regler URE 422 RA
On Request
Video encoder SU 08 AF 1
On Request
Videokabel VK 02/F AF 1
On Request
Videokabel VK 02/F AF 2
On Request
Videokabel VK 02/F AF 3
On Request
Pyrometer CellaCast PX 81
IO-Link IODD
Pyrometer CellaCast PX 81
IO-Link Manufacturer explanation
Pyrometer CellaCast PX 81
Field-of-view calculator
Pyrometer
PX 81 AF 11
(0,2 m - ∞)
PX 81 AF 11
(0,2 m - ∞)
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
8
16
24
32
40
48
56
64
72
80
88
96
104
112
120
128
136
144
152
160
168
176
184
192
200
1.05 mm
Measuring distance
Spot diameter
0.00 mm
21.50 mm
8.00 mm
20.68 mm
16.00 mm
19.86 mm
24.00 mm
19.05 mm
32.00 mm
18.23 mm
40.00 mm
17.41 mm
48.00 mm
16.59 mm
56.00 mm
15.77 mm
64.00 mm
14.96 mm
72.00 mm
14.14 mm
80.00 mm
13.32 mm
88.00 mm
12.50 mm
96.00 mm
11.69 mm
104.00 mm
10.87 mm
112.00 mm
10.05 mm
120.00 mm
9.23 mm
128.00 mm
8.41 mm
136.00 mm
7.60 mm
144.00 mm
6.78 mm
152.00 mm
5.96 mm
160.00 mm
5.14 mm
168.00 mm
4.32 mm
176.00 mm
3.51 mm
184.00 mm
2.69 mm
192.00 mm
1.87 mm
200.00 mm
1.05 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2023 –
Internetagentur
– Wrocklage Werbewerkstatt