Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaCombustion PA 47
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
Product Data Sheets
FAQs
Warranty Information
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaCombustion PA 47
Description
The CellaCombustion PA 47 is a special pyrometer for non-contact temperature measurement of sooty flames in coal-fired power stations and incineration plants. The measurement and signal processing, both based on the two-colour method, detect the heat radiation of the soot emitting particles of the flame in the near infrared range at two wavelengths. In order to correct the influence of the wavelength-dependent radiation properties of the soot particles and the optical density of flames, a special algorithm is used during the temperature determination. The flame temperature can be used to optimize burnout in the furnace operation, reduce pollutant emissions and minimize slagging of the combustion chamber walls.
Special features:
Measuring range 700 to 1ʼ °C
focusable lenses for exact adjustment of the measuring distance
broadband anti-reflective precision lens
LED display can be read from a great distance
test current output for the diagnostic function
standard feature: digital input/output as well as two analogue outputs and USB/RS 485 interface
Pyrometer CellaCombustion PA 47
Properties
Version
Measuring range
700 - 1700 °C
700 - 1700 °C
Focal distance
0,4 m - ∞
0,4 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Video camera
Your selection impact other settings.
Version
AF 1
Sighting option
Through-the-lens-sighting
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaCombustion PA 47 AF 1
Measuring range
700 - 1700 °C
Focal distance
0,4 m - ∞
Shape of the measurement area
round
Distance ratio
80 : 1
Objective
PZ 20.01
Measuring principle
two-colour
Sighting option
Through-the-lens-sighting
Sighting option
Video camera
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaCombustion PA 47
Technical Data
Optical variants
Lenses
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Electrical parameters
Analog input
0 - 10 V
Switching input
2 x to 24 V
Camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Functions
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Software
Software
CellaView
Pyrometer CellaCombustion PA 47
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCombustion PA 47
Downloads
X
Pyrometer CellaCombustion PA 47
Accessories
Electrical accessories
Mechanical accessories
Mountings
Adapter flange PB 08/J AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminium compact hose PB 08/L
On Request
Ball and socket mounting PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Digital display DA 570
On Request
Emissivity switching box VK 30.07
On Request
Fan PB 08/F AF 3
On Request
Fan PB 08/F AF 4
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange PZ 20/F-120
On Request
Flange PZ 20/F-120 DN50
On Request
Flange PZ 20/F-130
On Request
Flange PZ 20/F-145
On Request
Flange PZ 20/F-160
On Request
Flange PZ 20/F-50
On Request
Flange PZ 40/D
On Request
Flange PZ 40/N-130 AF 1
On Request
Flange PZ 40/N-130 AF 2
On Request
Flange tube PB 08/M AF1
On Request
Flange ZA 10/F-160
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Interface isolator SU 07 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
Junction box VA 20.01
On Request
Junction box VK 30.02
On Request
Junction box VK 30.04
On Request
Junction box VK 30.05
On Request
Material selector switch VK 30.01
On Request
Monitor system 0
On Request
Mounting angle PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting PA 15-001
On Request
Mounting PA 15-002
On Request
Mounting PA 15-003
On Request
Mounting PA 15-004
On Request
Mounting PA 15-005
On Request
Mounting PA 15-007
On Request
Mounting PA 15-008
On Request
Mounting PA 20-071
On Request
Mounting PB 08/K AF 2
On Request
Mounting PB 08/Q AF 1
On Request
Mounting socket PZ 20/G AF 1
On Request
Oscillating mirror PZ 20/X AF 5
On Request
Oscillating mirror PZ 20/X AF 6
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quartz window with hinge PZ 20/I AF 1
On Request
Quick coupling PA 20/D
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Spherical flange PB 08/I AF 3
On Request
Spherical flange PB 08/I AF 4
On Request
Steckernetzteil E2EFSW3 12W-24V
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Universal-Regler URE 422 RA
On Request
Video encoder SU 08 AF 1
On Request
Videokabel VK 02/F AF 1
On Request
Videokabel VK 02/F AF 2
On Request
Videokabel VK 02/F AF 3
On Request
Zubehör für Schnittstellen SU 02 AF 1
On Request
Pyrometer CellaCombustion PA 47
IO-Link IODD
Pyrometer CellaCombustion PA 47
IO-Link Manufacturer explanation
Pyrometer CellaCombustion PA 47
Field-of-view calculator
Pyrometer
PA 47 AF 1
(0,4 m - ∞)
PA 47 AF 1
(0,4 m - ∞)
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
5.00 mm
Measuring distance
Spot diameter
0.00 mm
18.50 mm
16.00 mm
17.96 mm
32.00 mm
17.42 mm
48.00 mm
16.88 mm
64.00 mm
16.34 mm
80.00 mm
15.80 mm
96.00 mm
15.26 mm
112.00 mm
14.72 mm
128.00 mm
14.18 mm
144.00 mm
13.64 mm
160.00 mm
13.10 mm
176.00 mm
12.56 mm
192.00 mm
12.02 mm
208.00 mm
11.48 mm
224.00 mm
10.94 mm
240.00 mm
10.40 mm
256.00 mm
9.86 mm
272.00 mm
9.32 mm
288.00 mm
8.78 mm
304.00 mm
8.24 mm
320.00 mm
7.70 mm
336.00 mm
7.16 mm
352.00 mm
6.62 mm
368.00 mm
6.08 mm
384.00 mm
5.54 mm
400.00 mm
5.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2023 –
Internetagentur
– Wrocklage Werbewerkstatt