Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaCombustion PK 62
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaCombustion PK 62
Article description
The CellaCombustion PK 62 is a special infrared thermometer for non-contact temperature measurement of sooty flames in coal-fired power stations and incineration plants. The measurement and signal processing, both based on the two-colour method, detect the heat radiation of the soot emitting particles of the flame in the near infrared range at two wavelengths. In order to correct the influence of the wavelength-dependent radiation properties of the soot particles and the optical density of flames, a special algorithm is used during the temperature determination. The flame temperature can be used to control the burnout in the furnace operation in order to reduce pollutant emissions and minimize slagging of the combustion chamber walls.
Special features:
Measuring range 700 to 1
700 °C -- analogue and switching output universally configurable -- high optical resolution due to precision lenses -- IO-Link interface -- all parameters can be set via pushbutton on the sensor -- very simple mounting via M30 central thread -- large and bright LED display
Pyrometer CellaCombustion PK 62
Properties
Version
Measuring range
700 - 1700 °C
700 - 1700 °C
Focal range
1,5 m
1,5 m
Your selection will impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaCombustion PK 62 AF 1
Measuring range
700 - 1700 °C
Measuring field
21 mm
Focal range
1,5 m
Shape of the measuring field
round
Measuring principle
two-color
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaCombustion PK 62
Technical Data
Measurement parameters
Measuring range
700 - 1700 °C
Sensor
Double photodiode
Spectral range
0,8 / 1,05 µm
Response time t90
≤ 10 ms (T > 650 °C)
Measurement uncertainty
1 % of temp. reading [°C]
Repeatability
2 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
Equipment
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin (A coded)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 210 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Transmittance
Damping time constant
Holding time of the peak picker
Operating mode and switching points of the switching contacts
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Simulation of temperature
Threshold value of the DTD function
Measuring channel two-colour, one-colour 1 and one-colour 2
Warning and cut-off threshold of the contamination monitoring
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value
DTD (Discontinuous Temperature Detection) function
Automatic temperature detection at discontinuous processes
Diagnostic function
Reverse polarity, overload and incorrect supply voltage indication
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrared thermometers CellaCombustion PK
Operating manual (short)
2 fastening nuts
Pyrometer CellaCombustion PK 62
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCombustion PK 62
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaCombustion PK
Quick guide CellaTemp PKxx IO-Link
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Pyrometer CellaCombustion PK 62
Accessories
Software
Electrical accessories
Mechanical accessories
Mounting solutions
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bayonet coupling PS 11/N AF 4
On Request
Bayonet coupling PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Cooling jacket PK 01/B AF 1
On Request
Cooling jacket PK 01/C AF 1
On Request
Cooling jacket PK 01/C AF 2
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Digital display DA 230A
On Request
Dust stop ZA 01/C
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.02
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting combinations PK 01-006
On Request
Mounting combinations PK 01-007
On Request
Mounting combinations PK 01-011
On Request
Mounting combinations PK 01-014
On Request
Mounting combinations PK 01-022
On Request
Mounting combinations PK 01-023
On Request
Mounting combinations PK 01-024
On Request
Mounting combinations PK 01-027
On Request
Mounting combinations PK 01-028
On Request
Mounting combinations PK 01-029
On Request
Mounting combinations PK 11-001
On Request
Mounting combinations PK 11-006
On Request
Mounting combinations PK 11-008
On Request
Mounting combinations PK 15-001
On Request
Mounting combinations PK 15-002
On Request
Mounting combinations PK 15-003
On Request
Mounting combinations PK 15-004
On Request
Mounting combinations PK 15-005
On Request
Mounting combinations PK 15-006
On Request
Mounting combinations PK 15-007
On Request
Mounting combinations PK 21-001
On Request
Mounting combinations PK 21-002
On Request
Mounting combinations PK 21-004
On Request
Mounting combinations PK 21-005
On Request
Mounting combinations PK 21-006
On Request
Mounting combinations PK 21-007
On Request
Mounting combinations PK 21-008
On Request
Mounting combinations PK 21-009
On Request
Mounting combinations PK 21-012
On Request
Mounting flange Flansch DN 50 - R1.1/4"
On Request
Plate ZA 01/S
On Request
Plate ZA 01/W
On Request
Sapphire disk hinge PZ 15/I AF 2
On Request
Sapphire protective window PS 15/I AF 1
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Thermal insulating tube PS 01/K
On Request
Tube cap ZA 01/A
On Request
Pyrometer CellaCombustion PK 62
IO-Link IODD
Type
Datei
Dateigröße
IODD PK62AF1_20221222.zip
470 KB
Download
Pyrometer CellaCombustion PK 62
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PK 62 AF 1_202302_en.pdf
100 KB
Download
Pyrometer CellaCombustion PK 62
Measurement field calculator
Pyrometer
PK 62 AF 1
(1,5 m)
PK 62 AF 1
(1,5 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
120
240
360
480
600
720
840
960
1080
1200
1320
1440
21.00 mm
Measuring distance
Measuring field diameter
0.00 mm
15.00 mm
60.00 mm
15.24 mm
120.00 mm
15.48 mm
180.00 mm
15.72 mm
240.00 mm
15.96 mm
300.00 mm
16.20 mm
360.00 mm
16.44 mm
420.00 mm
16.68 mm
480.00 mm
16.92 mm
540.00 mm
17.16 mm
600.00 mm
17.40 mm
660.00 mm
17.64 mm
720.00 mm
17.88 mm
780.00 mm
18.12 mm
840.00 mm
18.36 mm
900.00 mm
18.60 mm
960.00 mm
18.84 mm
1,020.00 mm
19.08 mm
1,080.00 mm
19.32 mm
1,140.00 mm
19.56 mm
1,200.00 mm
19.80 mm
1,260.00 mm
20.04 mm
1,320.00 mm
20.28 mm
1,380.00 mm
20.52 mm
1,440.00 mm
20.76 mm
1,500.00 mm
21.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt