Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaCombustion PK 73
Article description
The CellaCombustion PK 73 measures at a special wavelength at which the chemical components of the hot combustion gas have a high optical density. These devices are used in large combustion plants such as thermal waste disposal plants and coal-fired power plants.
Special features:
Measuring range 500 to 2
500 °C -- small/compact design -- switching output universally configurable -- high optical resolution due to precision lenses -- IO-Link interface -- all parameters can be set via pushbutton on the sensor or via interface from the plant control system -- test function can be triggered by pushbutton or control signal -- very simple mounting via M30 central thread -- large and bright LED display
Pyrometer CellaCombustion PK 73
Properties
Version
Measuring range
500 - 2500 °C
500 - 2500 °C
Focal range
0,4 m
0,4 m
Your selection will impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaCombustion PK 73 AF 1
Measuring range
500 - 2500 °C
Measuring field
7 mm
Focal range
0,4 m
Shape of the measuring field
round
Measuring principle
one-color
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaCombustion PK 73
Technical Data
Measurement parameters
Measuring range
500 - 2500 °C
Sensor
Thermopile
Spectral range
CO range
Response time t90
≤ 60 ms
Measurement uncertainty
1 % of temp. reading [°C]
Repeatability
4 K
Temperature coefficient
0.04 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
Equipment
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin (A coded)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 210 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Damping time constant
Holding time of the peak picker
Operating mode and switching points of the switching contact
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Simulation of temperature
Test function
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Test function
via pushbutton or test input
Service function
Simulation of a measured value
Diagnostic function
Reverse polarity, overload and incorrect supply voltage indication
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrared thermometers CellaCombustion PK
Operating manual (short)
2 fastening nuts
Pyrometer CellaCombustion PK 73
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaCombustion PK 73
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Application report CellaCombustion
Manual CellaCombustion PK
Quick guide CellaTemp PKxx IO-Link
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Pyrometer CellaCombustion PK 73
Accessories
Software
Electrical accessories
Mechanical accessories
Mounting solutions
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bayonet coupling PS 11/N AF 4
On Request
Bayonet coupling PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Cooling jacket PK 01/B AF 1
On Request
Cooling jacket PK 01/C AF 1
On Request
Cooling jacket PK 01/C AF 2
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Digital display DA 230A
On Request
Dust stop ZA 01/C
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.02
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting combinations PK 01-006
On Request
Mounting combinations PK 01-007
On Request
Mounting combinations PK 01-011
On Request
Mounting combinations PK 01-014
On Request
Mounting combinations PK 01-022
On Request
Mounting combinations PK 01-023
On Request
Mounting combinations PK 01-024
On Request
Mounting combinations PK 01-027
On Request
Mounting combinations PK 01-028
On Request
Mounting combinations PK 01-029
On Request
Mounting combinations PK 11-001
On Request
Mounting combinations PK 11-006
On Request
Mounting combinations PK 11-008
On Request
Mounting combinations PK 15-001
On Request
Mounting combinations PK 15-002
On Request
Mounting combinations PK 15-003
On Request
Mounting combinations PK 15-004
On Request
Mounting combinations PK 15-005
On Request
Mounting combinations PK 15-006
On Request
Mounting combinations PK 15-007
On Request
Mounting flange Flansch DN 50 - R1.1/4"
On Request
Plate ZA 01/S
On Request
Plate ZA 01/W
On Request
Sapphire disk hinge PZ 15/I AF 2
On Request
Sapphire protective window PS 15/I AF 1
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Thermal insulating tube PS 01/K
On Request
Tube cap ZA 01/A
On Request
Pyrometer CellaCombustion PK 73
IO-Link IODD
Type
Datei
Dateigröße
IODD PK73AF1_20180806.zip
383 KB
Download
Pyrometer CellaCombustion PK 73
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PK 73 AF 1_201808_en.pdf
365 KB
Download
Pyrometer CellaCombustion PK 73
Measurement field calculator
Pyrometer
PK 73 AF 1
(0,4 m)
PK 73 AF 1
(0,4 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
7.00 mm
Measuring distance
Measuring field diameter
0.00 mm
18.20 mm
16.00 mm
17.75 mm
32.00 mm
17.30 mm
48.00 mm
16.86 mm
64.00 mm
16.41 mm
80.00 mm
15.96 mm
96.00 mm
15.51 mm
112.00 mm
15.06 mm
128.00 mm
14.62 mm
144.00 mm
14.17 mm
160.00 mm
13.72 mm
176.00 mm
13.27 mm
192.00 mm
12.82 mm
208.00 mm
12.38 mm
224.00 mm
11.93 mm
240.00 mm
11.48 mm
256.00 mm
11.03 mm
272.00 mm
10.58 mm
288.00 mm
10.14 mm
304.00 mm
9.69 mm
320.00 mm
9.24 mm
336.00 mm
8.79 mm
352.00 mm
8.34 mm
368.00 mm
7.90 mm
384.00 mm
7.45 mm
400.00 mm
7.00 mm
Request a quote