Pyrometer CellaCombustion PX 18

Article description

The CellaCombustion PX 18 measures at a special wavelength at which the chemical components of the hot combustion gas have a high optical density. These devices are used in large combustion plants such as thermal waste disposal plants and coal-fired power plants.

Special features:
  • Measuring range 500 to 2
  • 500 °C -- modern IO-Link interface -- focusable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lens -- LED display can be read from a great distance -- test current output for the diagnostic function -- 1 analogue output and 2 switching outputs -- source freely configurable


Pyrometer CellaCombustion PX 18
Measuring range
Focal range
Your selection will impact other settings.
You can request this article from us
More information about IO-Link:

Version CellaCombustion PX 18 AF 1 
Measuring range 500 - 2500 °C 
Focal range 0,8 m - ∞ 
Shape of the measuring field round 
Distance ratio 70 : 1 
Objective PZ 15.03 
Measuring principle one-color 
Sighting option Through-the-lens sighting 
Sighting option Laser pilot light 
Sighting option Video camera 