Start page
Media library
watch list
Contact
Search
Log in
Shopping cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometers
Product finder
Pyrometer CellaPort PT 110
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Pyrometers
Pyrometers
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
Application solutions
Contact
Contact
Support
FAQs
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
IO-Link
Pyrometer CellaPort PT 110
Article description
The CellaPort PT 110 is a digital pyrometer for measuring temperatures from 0 to 1,000 °C. Due to the very large measuring span, it can be used very universally for a variety of applications, primarily on non-metallic measuring objects. A through-the-lens sighting is available for easy and precise sighting of the measuring object. The LED display on the back can be read from a great distance. In normal operation, the current measuring temperature is displayed. If current parameters are changed via the rear buttons, the changed settings are shown on the display.
Special features:
Measuring range 0 to 1
000 °C -- focusable interchangeable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lenses -- LED display -- standard feature: USB interface
Pyrometer CellaPort PT 110
Properties
Version
Measuring range
0 - 1000 °C
0 - 1000 °C
Focal range
0,15 - 0,3 m
0,15 - 0,3 m
0,3 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Your selection will impact other settings.
Version
AF 1
AF 2
Sight
Through-the-lens sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaPort PT 110 AF 1
Version
CellaPort PT 110 AF 2
Measuring range
0 - 1000 °C
Measuring range
0 - 1000 °C
Focal range
0,3 m - ∞
Focal range
0,15 - 0,3 m
Shape of the measuring field
round
Distance ratio
50 : 1
Distance ratio
48 : 1
Objective
PZ 10.01
Objective
PZ 10.05
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaPort PT 110
Technical Data
Measurement parameters
Measuring range
0 - 1000 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t98
≤ 30 ms
Measurement uncertainty
1 % of temp. reading [°C] min. 2 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Optical variants
Objective lenses
Standard-Objektiv PZ 10.01: Fokussierung 0,3 m - ∞
Close-up lens PZ 10.05: focusing 0.15 m - 0.3 m
Electrical parameters
Interface
USB
Power supply
Built-in rechargeable battery
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Equipment
Sighting option
through-the-lens sighting
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED external
3 x LED internal
Operator controls
3 pushbuttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing material
Aluminum
Type of protection
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of background radiation
Smoothing filter
Operating mode and holding time of the measured value memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Functions
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Pyrometer CellaPort PT 110
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaPort PT 110
Downloads
Brochure CellaPort PT
Brochure CellaView
Manual CellaPort PT 11x 12x 13
Quick guide CellaPort PT 11x 12x 13x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaPort PT 110
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
carrying case PT 110/A
On Request
Close-up optics PZ 10.05
On Request
Floor stand PT 50/B AF 2
On Request
Lens cap 94246
On Request
Plug-in power supply NN090P080PGS
On Request
Standard optics PZ 10.01
On Request
Vorsatzlinsen für PZ 10 PZ 10/A
On Request
Pyrometer CellaPort PT 110
IO-Link IODD
Pyrometer CellaPort PT 110
IO-Link Manufacturer declaration
Pyrometer CellaPort PT 110
Measurement field calculator
Pyrometer
PT 110 AF 1
(0,3 m - ∞)
PT 110 AF 2
(0,15 - 0,3 m)
PT 110 AF 1
(0,3 m - ∞)
Supplementary lens
none
PZ 10/A
(0,036 - 0,042 m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
6.00 mm
Measuring distance
Measuring field diameter
0.00 mm
24.00 mm
12.00 mm
23.28 mm
24.00 mm
22.56 mm
36.00 mm
21.84 mm
48.00 mm
21.12 mm
60.00 mm
20.40 mm
72.00 mm
19.68 mm
84.00 mm
18.96 mm
96.00 mm
18.24 mm
108.00 mm
17.52 mm
120.00 mm
16.80 mm
132.00 mm
16.08 mm
144.00 mm
15.36 mm
156.00 mm
14.64 mm
168.00 mm
13.92 mm
180.00 mm
13.20 mm
192.00 mm
12.48 mm
204.00 mm
11.76 mm
216.00 mm
11.04 mm
228.00 mm
10.32 mm
240.00 mm
9.60 mm
252.00 mm
8.88 mm
264.00 mm
8.16 mm
276.00 mm
7.44 mm
288.00 mm
6.72 mm
300.00 mm
6.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2025 –
Internetagentur
– Wrocklage Werbewerkstatt