Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaPort PT 120
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaPort PT 120
Description
The CellaPort PT 120 is a digital pyrometer for measuring temperatures from 250 to 2,000 °C. Due to the very large measuring span, it can be used very universally for a variety of applications. A through-the-lens sighting is available for easy and precise sighting of the measuring object. Parameters such as emissivity, measuring range or smoothing constants can be set with the rear buttons. The changed parameters are shown on the LED display. In normal operation, the current measuring temperature is displayed.
Special features:
Measuring range 250 to 2
000 °C
focusable lenses for exact adjustment of the measuring distance
broadband anti-reflective precision lens
LED display
standard feature: USB interface
Pyrometer CellaPort PT 120
Properties
Version
Measuring range
250 - 2000 °C
250 - 2000 °C
Focal distance
0,2 - 0,4 m
0,2 - 0,4 m
0,2 m - ∞
0,4 m - ∞
1,2 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Your selection impact other settings.
Version
AF 1
AF 2
AF 3
AF 4
Sighting option
Through-the-lens-sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaPort PT 120 AF 1
Version
CellaPort PT 120 AF 2
Version
CellaPort PT 120 AF 3
Version
CellaPort PT 120 AF 4
Measuring range
250 - 2000 °C
Measuring range
250 - 2000 °C
Measuring range
250 - 2000 °C
Measuring range
250 - 2000 °C
Focal distance
0,4 m - ∞
Focal distance
0,2 - 0,4 m
Focal distance
1,2 m - ∞
Focal distance
0,2 m - ∞
Shape of the measurement area
round
Distance ratio
175 : 1
Distance ratio
150 : 1
Distance ratio
275 : 1
Distance ratio
40 : 1
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Objective
PZ 20.05
Measuring principle
one-colour
Sighting option
Through-the-lens-sighting
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaPort PT 120
Technical Data
Measurement parameters
Measuring range
250 - 2000 °C
Sensor
Photo diode
Spectral range
1.1 - 1.7 µm
Response time t98
≤ 50 ms (T > 250 °C)
≤ 2 ms (T > 750 °C)
Measurement uncertainty
0.3 % of temp. reading [°C], min. 4 K
Repeatability
1 K
Temperature coefficient
0.25 K/K (T < 500 °C)
0.05 %/K (T > 500 °C)
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Lenses
Standard lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Electrical parameters
Interface
USB
Power supply
Rechargeable battery pack
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Features
Sighting option
Through-the-lens-sighting
Display
4-digit LED display red, digit-height 8 mm
Status display
2 x LED external
3 x LED internal
Control elements
3 buttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing
Aluminium
Protection class
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of the reflected ambient radiation
Smoothing filter
Operation mode and hold time of the data memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Functions
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
Software
CellaView
Pyrometer CellaPort PT 120
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaPort PT 120
Downloads
Brochure CellaPort PT
Brochure Supplementary lenses
Brochure CellaView
Manual CellaPort PT 11x 12x 13
Quick guide CellaPort PT 11x 12x 13x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaPort PT 120
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Bodenstativ PT 50/B AF 2
On Request
CD - Software CellaView SW 40 AF 1
Close-up optics PZ 20.03
On Request
Koffer PT 110/A
On Request
Lens system PZ 20.08
On Request
Objektivdeckel 94246
On Request
Okular PT 120.01
On Request
Okular PT 120.02
On Request
PT Option "/O" PT/O
On Request
Quartz protective window 70146
On Request
Standard optics PZ 20.01
On Request
Steckernetzteil NN090P080PGS
On Request
Supplementary lens PZ 20/O-120
On Request
Supplementary lens PZ 20/O-75
On Request
Tele-optics PZ 20.06
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-50
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-63
On Request
Wide-angle optics PZ 20.05
On Request
Pyrometer CellaPort PT 120
IO-Link IODD
Pyrometer CellaPort PT 120
IO-Link Manufacturer explanation
Pyrometer CellaPort PT 120
Field-of-view calculator
Pyrometer
PT 120 AF 1
(0,4 m - ∞)
PT 120 AF 2
(0,2 - 0,4 m)
PT 120 AF 3
(1,2 m - ∞)
PT 120 AF 4
(0,2 m - ∞)
PT 120 AF 1
(0,4 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,036 - 0,041 m)
PZ 20/O-63
(0,045 - 0,054 m)
PZ 20/O-75
(0,052 - 0,063 m)
PZ 20/O-120
(0,084 - 0,112 m)
none
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
2.29 mm
Measuring distance
Spot diameter
0.00 mm
18.00 mm
16.00 mm
17.37 mm
32.00 mm
16.74 mm
48.00 mm
16.11 mm
64.00 mm
15.49 mm
80.00 mm
14.86 mm
96.00 mm
14.23 mm
112.00 mm
13.60 mm
128.00 mm
12.97 mm
144.00 mm
12.34 mm
160.00 mm
11.71 mm
176.00 mm
11.09 mm
192.00 mm
10.46 mm
208.00 mm
9.83 mm
224.00 mm
9.20 mm
240.00 mm
8.57 mm
256.00 mm
7.94 mm
272.00 mm
7.31 mm
288.00 mm
6.69 mm
304.00 mm
6.06 mm
320.00 mm
5.43 mm
336.00 mm
4.80 mm
352.00 mm
4.17 mm
368.00 mm
3.54 mm
384.00 mm
2.91 mm
400.00 mm
2.29 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2023 –
Internetagentur
– Wrocklage Werbewerkstatt