Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaPort PT 129
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaPort PT 129
Description
The CellaPort PT 129 is equipped with a special blocking filter. As a result, the measurement is not affected by daylight. This pyrometer also responds substantially less sensitive on reflective external radiation from hot objects around than conventional devices working at short wavelengths. This means that the CellaPort PT 129 can be used for a wide variety of applications in the metalworking industry and in particular for measuring the temperature of aluminium and bare metals at low temperatures. Due to the blocking filter, it can also be used for measurements in processes in which diode, Nd:YAG or CO2 lasers are used for heating. The energetically high laser radiation does not influence the measurement.
Special features:
Measuring range 150 to 1,200 °C
focusable lens for exact adjustment of the measuring distance
broadband anti-reflective precision lens
particularly suitable for measurements on metals
LED display
standard feature: USB interface
Pyrometer CellaPort PT 129
Properties
Version
Measuring range
150 - 800 °C
150 - 800 °C
180 - 1200 °C
Focal distance
0,2 - 0,4 m
0,2 - 0,4 m
0,3 m - ∞
0,4 m - ∞
1,2 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Your selection impact other settings.
Version
AF 10
AF 21
AF 22
AF 23
Sighting option
Through-the-lens-sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaPort PT 129 AF 10
Version
CellaPort PT 129 AF 21
Version
CellaPort PT 129 AF 22
Version
CellaPort PT 129 AF 23
Measuring range
150 - 800 °C
Measuring range
180 - 1200 °C
Measuring range
180 - 1200 °C
Measuring range
180 - 1200 °C
Focal distance
0,3 m - ∞
Focal distance
0,4 m - ∞
Focal distance
0,2 - 0,4 m
Focal distance
1,2 m - ∞
Shape of the measurement area
round
Distance ratio
48 : 1
Distance ratio
60 : 1
Distance ratio
56 : 1
Distance ratio
96 : 1
Objective
PZ 20.08
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Measuring principle
one-colour
Sighting option
Through-the-lens-sighting
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaPort PT 129
Technical Data
Measurement parameters
Measuring range
150 - 1200 °C in several segments
Sensor
Photo diode
Spectral range
1.8 - 2.2 µm
Response time t98
Measuring range 150 - 800 °C:
≤ 50 ms (T > 150 °C)
≤ 15 ms (T > 200 °C)
≤ 2 ms (T > 350 °C)
Measuring range 180 - 1200 °C:
≤ 75 ms (T > 180 °C)
≤ 35 ms (T > 200 °C)
≤ 5 ms (T > 300 °C)
≤ 2 ms (T > 600 °C)
Measurement uncertainty
0.75 % of temp. reading [°C], min. 5 K
Repeatability
1 K
Temperature coefficient
0.25 K/K (T < 500 °C)
0.05 %/K (T > 500 °C)
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Optical variants
Lenses
Measuring range 150 - 800 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Measuring range 180 - 1200 °C:
Standard lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Electrical parameters
Interface
USB
Power supply
Rechargeable battery pack
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Features
Sighting option
Through-the-lens-sighting
Display
4-digit LED display red, digit-height 8 mm
Status display
2 x LED external
3 x LED internal
Control elements
3 buttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing
Aluminium
Protection class
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of the reflected ambient radiation
Smoothing filter
Operation mode and hold time of the data memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Functions
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
Software
CellaView
Pyrometer CellaPort PT 129
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaPort PT 129
Downloads
Brochure CellaPort PT
Brochure Supplementary lenses
Brochure CellaView
Manual CellaPort PT 11x 12x 13
Quick guide CellaPort PT 11x 12x 13x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaPort PT 129
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Bodenstativ PT 50/B AF 2
On Request
CD - Software CellaView SW 40 AF 1
Koffer PT 110/A
On Request
Objektivdeckel 94246
On Request
Okular PT 120.01
On Request
Okular PT 120.02
On Request
PT Option "/O" PT/O
On Request
Steckernetzteil NN090P080PGS
On Request
Pyrometer CellaPort PT 129
IO-Link IODD
Pyrometer CellaPort PT 129
IO-Link Manufacturer explanation
Pyrometer CellaPort PT 129
Field-of-view calculator
Pyrometer
PT 129 AF 10
(0,3 m - ∞)
PT 129 AF 21
(0,4 m - ∞)
PT 129 AF 22
(0,2 - 0,4 m)
PT 129 AF 23
(1,2 m - ∞)
PT 129 AF 10
(0,3 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,034 - 0,041m)
none
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
6.25 mm
Measuring distance
Spot diameter
0.00 mm
24.50 mm
12.00 mm
23.77 mm
24.00 mm
23.04 mm
36.00 mm
22.31 mm
48.00 mm
21.58 mm
60.00 mm
20.85 mm
72.00 mm
20.12 mm
84.00 mm
19.39 mm
96.00 mm
18.66 mm
108.00 mm
17.93 mm
120.00 mm
17.20 mm
132.00 mm
16.47 mm
144.00 mm
15.74 mm
156.00 mm
15.01 mm
168.00 mm
14.28 mm
180.00 mm
13.55 mm
192.00 mm
12.82 mm
204.00 mm
12.09 mm
216.00 mm
11.36 mm
228.00 mm
10.63 mm
240.00 mm
9.90 mm
252.00 mm
9.17 mm
264.00 mm
8.44 mm
276.00 mm
7.71 mm
288.00 mm
6.98 mm
300.00 mm
6.25 mm