Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaPort PT 129
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaPort PT 129
Article description
The CellaPort PT 129 is equipped with a special blocking filter. As a result, the measurement is not affected by daylight. This pyrometer also responds substantially less sensitive on reflective external radiation from hot objects around than conventional devices working at short wavelengths. This means that the CellaPort PT 129 can be used for a wide variety of applications in the metalworking industry and in particular for measuring the temperature of aluminium and bare metals at low temperatures. Due to the blocking filter, it can also be used for measurements in processes in which diode, Nd:YAG or CO2 lasers are used for heating. The energetically high laser radiation does not influence the measurement.
Special features:
Measuring range 150 to 1
200 °C -- focusable lens for exact adjustment of the measuring distance -- broadband anti-reflective precision lens -- particularly suitable for measurements on metals -- LED display -- standard feature: USB interface
Pyrometer CellaPort PT 129
Properties
Version
Measuring range
150 - 800 °C
150 - 800 °C
180 - 1200 °C
Focal range
0,2 - 0,4 m
0,2 - 0,4 m
0,3 m - ∞
0,4 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Your selection will impact other settings.
Version
AF 10
AF 21
AF 22
AF 23
Sight
Through-the-lens sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaPort PT 129 AF 10
Version
CellaPort PT 129 AF 21
Version
CellaPort PT 129 AF 22
Version
CellaPort PT 129 AF 23
Measuring range
150 - 800 °C
Measuring range
180 - 1200 °C
Measuring range
180 - 1200 °C
Measuring range
180 - 1200 °C
Focal range
0,3 m - ∞
Focal range
0,4 m - ∞
Focal range
0,2 - 0,4 m
Focal range
1,2 m - ∞
Shape of the measuring field
round
Distance ratio
48 : 1
Distance ratio
60 : 1
Distance ratio
56 : 1
Distance ratio
96 : 1
Objective
PZ 20.08
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaPort PT 129
Technical Data
Measurement parameters
Measuring range
150 - 1,200 °C in sub-ranges
Sensor
Photodiode
Spectral range
1.8 - 2.2 µm
Response time t98
Measuring range 150 - 800 °C:
≤ 50 ms (T > 150 °C)
≤ 15 ms (T > 200 °C)
≤ 2 ms (T > 350 °C)
Measuring range 180 - 1,200 °C:
≤ 75 ms (T > 180 °C)
≤ 35 ms (T > 200 °C)
≤ 5 ms (T > 300 °C)
≤ 2 ms (T > 600 °C)
Measurement uncertainty
0.75 % of temp. reading [°C] min. 5 K
Repeatability
1 K
Temperature coefficient
0.25 K/K (T < 500 °C)
0.05 %/K (T > 500 °C)
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Optical variants
Objective lenses
Measuring range 150 - 800 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Measuring range 180 - 1,200 °C:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Electrical parameters
Interface
USB
Power supply
Built-in rechargeable battery
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Equipment
Sighting option
through-the-lens sighting
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED external
3 x LED internal
Operator controls
3 pushbuttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing material
Aluminum
Type of protection
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of background radiation
Smoothing filter
Operating mode and holding time of the measured value memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Functions
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Pyrometer CellaPort PT 129
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaPort PT 129
Downloads
Brochure CellaPort PT
Brochure Supplementary lenses
Brochure CellaView
Manual CellaPort PT 11x 12x 13
Quick guide CellaPort PT 11x 12x 13x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaPort PT 129
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
carrying case PT 110/A
On Request
Eyepiece PT 120.01
On Request
Eyepiece PT 120.02
On Request
Floor stand PT 50/B AF 2
On Request
Lens cap 94246
On Request
Plug-in power supply NN090P080PGS
On Request
PT Option "/O" PT/O
On Request
Pyrometer CellaPort PT 129
IO-Link IODD
Pyrometer CellaPort PT 129
IO-Link Manufacturer declaration
Pyrometer CellaPort PT 129
Measurement field calculator
Pyrometer
PT 129 AF 10
(0,3 m - ∞)
PT 129 AF 21
(0,4 m - ∞)
PT 129 AF 22
(0,2 - 0,4 m)
PT 129 AF 23
(1,2 m - ∞)
PT 129 AF 10
(0,3 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,034 - 0,041m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
6.25 mm
Measuring distance
Measuring field diameter
0.00 mm
24.50 mm
12.00 mm
23.77 mm
24.00 mm
23.04 mm
36.00 mm
22.31 mm
48.00 mm
21.58 mm
60.00 mm
20.85 mm
72.00 mm
20.12 mm
84.00 mm
19.39 mm
96.00 mm
18.66 mm
108.00 mm
17.93 mm
120.00 mm
17.20 mm
132.00 mm
16.47 mm
144.00 mm
15.74 mm
156.00 mm
15.01 mm
168.00 mm
14.28 mm
180.00 mm
13.55 mm
192.00 mm
12.82 mm
204.00 mm
12.09 mm
216.00 mm
11.36 mm
228.00 mm
10.63 mm
240.00 mm
9.90 mm
252.00 mm
9.17 mm
264.00 mm
8.44 mm
276.00 mm
7.71 mm
288.00 mm
6.98 mm
300.00 mm
6.25 mm