Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaPort PT 143
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaPort PT 143
Article description
The CellaPort PT 143 panorama pyrometer® has a rectangular measuring field within which the measuring object can move freely. This enables the safe measurement of moving objects such as vibrating wires. The rectangular measuring field is also more advantageous when the position of the object (for example billets or metal rods) varies on the roller table. Even with very small objects such as filaments, the alignment of a mobile device with a rectangular measuring field is much easier than with a round measuring field.
Special features:
Measuring range 600 to 2
400 °C -- focusable lens with rectangular measuring field -- broadband anti-reflective precision lenses -- short measuring wavelengths -- LED display -- standard feature: USB interface
Pyrometer CellaPort PT 143
Properties
Version
Measuring range
600 - 1400 °C
600 - 1400 °C
650 - 1700 °C
750 - 2400 °C
Focal range
0,2 - 0,4 m
0,2 - 0,4 m
0,2 m - ∞
0,3 m - ∞
0,4 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Your selection will impact other settings.
Version
AF 1
AF 2
AF 3
AF 4
AF 5
AF 6
AF 10
AF 11
AF 13
AF 14
AF 20
Sight
Through-the-lens sighting
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaPort PT 143 AF 1
Version
CellaPort PT 143 AF 2
Version
CellaPort PT 143 AF 3
Version
CellaPort PT 143 AF 4
Version
CellaPort PT 143 AF 5
Version
CellaPort PT 143 AF 6
Version
CellaPort PT 143 AF 10
Version
CellaPort PT 143 AF 11
Version
CellaPort PT 143 AF 13
Version
CellaPort PT 143 AF 14
Version
CellaPort PT 143 AF 20
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Measuring range
650 - 1700 °C
Measuring range
750 - 2400 °C
Measuring range
750 - 2400 °C
Measuring range
750 - 2400 °C
Measuring range
650 - 1700 °C
Measuring range
750 - 2400 °C
Measuring range
650 - 1700 °C
Measuring range
750 - 2400 °C
Measuring range
600 - 1400 °C
Focal range
0,4 m - ∞
Focal range
0,2 - 0,4 m
Focal range
1,2 m - ∞
Focal range
0,4 m - ∞
Focal range
0,2 - 0,4 m
Focal range
1,2 m - ∞
Focal range
0,2 m - ∞
Focal range
0,2 m - ∞
Focal range
0,3 m - ∞
Focal range
0,3 m - ∞
Focal range
0,3 m - ∞
Shape of the measuring field
rectangular
Distance ratio
45:1 / 230:1
Distance ratio
40:1 / 215:1
Distance ratio
75:1 / 375:1
Distance ratio
50:1 / 350:1
Distance ratio
45:1 / 330:1
Distance ratio
85:1 / 580:1
Distance ratio
10:1 / 55:1
Distance ratio
11:1 / 85:1
Distance ratio
30:1 / 150:1
Distance ratio
34:1 / 230:1
Distance ratio
30:1 / 150:1
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Objective
PZ 20.05
Objective
PZ 20.05
Objective
PZ 20.08
Objective
PZ 20.08
Objective
PZ 20.08
Measuring principle
two-color
Sighting option
Through-the-lens sighting
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaPort PT 143
Technical Data
Measurement parameters
Measuring range
500 - 2400 °C in Teilbereichen
Sensor
Double photodiode
Spectral range
0.95 / 1.05 µm
Response time t98
Measuring range 600 - 1,400 °C and 650 - 1,700 °C:
≤ 10 ms (T > 750 °C)
Measuring range 750 - 2,400 °C:
≤ 10 ms (T > 950 °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Objective lenses
Measuring range 600 - 1,400 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Measuring range 650 - 1,700 °C and 750 - 2,400 °C:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Electrical parameters
Interface
USB
Power supply
Built-in rechargeable battery
Battery life: approx. 15 hours (based on continuous operation at Ta=23 °C)
Equipment
Sighting option
through-the-lens sighting
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED external
3 x LED internal
Operator controls
3 pushbuttons
General parameters
Ambient temperature
0 - 50 °C
Storage temperature
-20 - +60 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 197 mm (plus lens length)
Housing material
Aluminum
Type of protection
IP 40 acc. to DIN 40050
Weight
approx. 1.1 kg
Adjustable parameters
Parameters
Emissivity
Locations of the emissivity tables
Transmittance
Compensation of background radiation
Smoothing filter
Operating mode and holding time of the measured value memory
Parameters of the ATD function
Linearization function
Status display of the LEDs
Temperature unit °C/°F
Automatic shutdown
Measuring channel two-colour - one-colour
Threshold value of the signal monitoring
Functions
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaPort PT
Protective and carrying case
Charger
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
Software
Software
CellaView
Pyrometer CellaPort PT 143
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaPort PT 143
Downloads
Brochure CellaPort PT
Brochure Supplementary lenses
Brochure CellaView
Manual CellaPort PT 14x 16x
Quick guide CellaPort PT 14x 16x
UKCA Declaration of Conformity PT1xx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaPort PT 143
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
carrying case PT 110/A
On Request
Close-up optics PZ 20.03
On Request
Eyepiece PT 120.01
On Request
Eyepiece PT 120.02
On Request
Floor stand PT 50/B AF 2
On Request
Lens cap 94246
On Request
Lens PZ 20.08
On Request
Plug-in power supply NN090P080PGS
On Request
Quartz protective window 70146
On Request
Standard optics PZ 20.01
On Request
Supplementary lens PZ 20/O-120
On Request
Supplementary lens PZ 20/O-75
On Request
Tele-optics PZ 20.06
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-50
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-63
On Request
Wide-angle optics PZ 20.05
On Request
Pyrometer CellaPort PT 143
IO-Link IODD
Pyrometer CellaPort PT 143
IO-Link Manufacturer declaration
Pyrometer CellaPort PT 143
Measurement field calculator
Pyrometer
PT 143 AF 1
(0,4 m - ∞)
PT 143 AF 10
(0,2 m - ∞)
PT 143 AF 11
(0,2 m - ∞)
PT 143 AF 13
(0,3 m - ∞)
PT 143 AF 14
(0,3 m - ∞)
PT 143 AF 2
(0,2 - 0,4 m)
PT 143 AF 20
(0,3 m - ∞)
PT 143 AF 3
(1,2 m - ∞)
PT 143 AF 4
(0,4 m - ∞)
PT 143 AF 5
(0,2 - 0,4 m)
PT 143 AF 6
(1,2 m - ∞)
PT 143 AF 1
(0,4 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,036 - 0,041 m)
PZ 20/O-63
(0,045 - 0,054 m)
PZ 20/O-75
(0,052 - 0,063 m)
PZ 20/O-120
(0,084 - 0,112 m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
8.89 x
1.74 mm
Measuring distance
Messfeldbreite
Messfeldhöhe
0.00 mm
19.00 mm
19.00 mm
16.00 mm
18.60 mm
18.31 mm
32.00 mm
18.19 mm
17.62 mm
48.00 mm
17.79 mm
16.93 mm
64.00 mm
17.38 mm
16.24 mm
80.00 mm
16.98 mm
15.55 mm
96.00 mm
16.57 mm
14.86 mm
112.00 mm
16.17 mm
14.17 mm
128.00 mm
15.76 mm
13.48 mm
144.00 mm
15.36 mm
12.79 mm
160.00 mm
14.96 mm
12.10 mm
176.00 mm
14.55 mm
11.41 mm
192.00 mm
14.15 mm
10.71 mm
208.00 mm
13.74 mm
10.02 mm
224.00 mm
13.34 mm
9.33 mm
240.00 mm
12.93 mm
8.64 mm
256.00 mm
12.53 mm
7.95 mm
272.00 mm
12.12 mm
7.26 mm
288.00 mm
11.72 mm
6.57 mm
304.00 mm
11.32 mm
5.88 mm
320.00 mm
10.91 mm
5.19 mm
336.00 mm
10.51 mm
4.50 mm
352.00 mm
10.10 mm
3.81 mm
368.00 mm
9.70 mm
3.12 mm
384.00 mm
9.29 mm
2.43 mm
400.00 mm
8.89 mm
1.74 mm