Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaSwitch PKS 10
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaSwitch PKS 10
Article description
Special features:
Pyrometer CellaSwitch PKS 10
Properties
Version
Measuring range
0 - 1000 °C
0 - 1000 °C
Focal range
0,3 m
0,3 m
Your selection will impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaSwitch PKS 10 AF 1
Measuring range
0 - 1000 °C
Measuring field
12 mm
Focal range
0,3 m
Shape of the measuring field
round
Measuring principle
one-color
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaSwitch PKS 10
Technical Data
Measurement parameters
Measuring range
50 - 500 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t90
≤ 100 ms
Measurement uncertainty
1 % of the range's final value
Resolution interface
4,5 K (1 %)
Resolution display
4,5 K (1 %)
Electrical parameters
Switching output
2 NO (normally open) contacts PNP ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Power supply
10 - 34 V DC
Ripple ≤ 200 mV
Current consumption
≤ 30 mA at 24 V DC without load current
Equipment
Display
two 7 segments LED, red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 connector, 5-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 155 mm (without plug)
Housing material
Stainless steel
Type of protection
IP 65 acc. to DIN 40050
Weight
0.235 kg
Adjustable parameters
Parameters
Switch-on and switch-off point successively 1 % of the temperature range
Switching function: N.O. / N.C. contact
Switch-on and switch-off delay 0 to 9.9 sec, gradually 0.1 sec
Functions
Test function
via operating menu or via external control signal
Scope of delivery
Scope of delivery
Infrared sensor PKS 10
Operating manual
2 fastening nuts
Pyrometer CellaSwitch PKS 10
Emissivity calculator
Keine Daten gefunden!
Pyrometer CellaSwitch PKS 10
Downloads
Declaration of conformity Declaration of Conformity PKSxx
UKCA Declaration of Conformity PKSxx
X
Pyrometer CellaSwitch PKS 10
Accessories
Electrical accessories
Mechanical accessories
Mounting solutions
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bayonet coupling PS 11/N AF 4
On Request
Bayonet coupling PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Cooling jacket PK 01/B AF 1
On Request
Cooling jacket PK 01/C AF 1
On Request
Cooling jacket PK 01/C AF 2
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Dust stop ZA 01/C
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting combinations PK 01-006
On Request
Mounting combinations PK 01-007
On Request
Mounting combinations PK 01-011
On Request
Mounting combinations PK 01-014
On Request
Mounting combinations PK 01-022
On Request
Mounting combinations PK 01-023
On Request
Mounting combinations PK 01-024
On Request
Mounting combinations PK 01-027
On Request
Mounting combinations PK 01-028
On Request
Mounting combinations PK 01-029
On Request
Mounting combinations PK 11-001
On Request
Mounting combinations PK 11-006
On Request
Mounting combinations PK 11-008
On Request
Mounting flange Flansch DN 50 - R1.1/4"
On Request
Plate ZA 01/S
On Request
Plate ZA 01/W
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Thermal insulating tube PS 01/K
On Request
Tube cap ZA 01/A
On Request
ZnS window PS 11/D AF 2
On Request
Pyrometer CellaSwitch PKS 10
IO-Link IODD
Pyrometer CellaSwitch PKS 10
IO-Link Manufacturer declaration
Pyrometer CellaSwitch PKS 10
Measurement field calculator
Pyrometer
PKS 10 AF 1
(0,3 m)
PKS 10 AF 1
(0,3 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
12.00 mm
Measuring distance
Measuring field diameter
0.00 mm
13.00 mm
12.00 mm
12.96 mm
24.00 mm
12.92 mm
36.00 mm
12.88 mm
48.00 mm
12.84 mm
60.00 mm
12.80 mm
72.00 mm
12.76 mm
84.00 mm
12.72 mm
96.00 mm
12.68 mm
108.00 mm
12.64 mm
120.00 mm
12.60 mm
132.00 mm
12.56 mm
144.00 mm
12.52 mm
156.00 mm
12.48 mm
168.00 mm
12.44 mm
180.00 mm
12.40 mm
192.00 mm
12.36 mm
204.00 mm
12.32 mm
216.00 mm
12.28 mm
228.00 mm
12.24 mm
240.00 mm
12.20 mm
252.00 mm
12.16 mm
264.00 mm
12.12 mm
276.00 mm
12.08 mm
288.00 mm
12.04 mm
300.00 mm
12.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt