Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PA 41
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PA 41
Article description
The CellaTemp® PA 41 is a digital two-colour pyrometer with a fibre optic cable for measuring temperatures between 700 and 3,000 °C. The two-colour pyrometer is equipped with a separate optical measuring head and a fibre optic cable. The fibre optic cable and measuring head are insensitive to interference from electromagnetic radiation and can be used in ambient temperatures up to 250 °C without cooling. The variant with separate optical measuring head has advantages especially in confined spaces.
Special features:
Measuring range 700 to 3
000 °C -- focusable interchangeable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lenses -- short measuring wavelengths -- LED display can be read from a great distance -- test current output for the diagnostic function -- standard feature: analogue output and USB/RS 485 interface -- measuring head and fibre optic cable heat resistant up to 250 °C
Pyrometer CellaTemp PA 41
Properties
Version
Measuring range
1100 - 3000 °C
1100 - 3000 °C
700 - 1800 °C
800 - 2400 °C
900 - 3000 °C
Focal range
0,033 - 0,045 m
0,033 - 0,045 m
0,12 m - ∞
0,2 m - ∞
0,5 m - ∞
1,8 m
Sight
Laser pilot light
Laser pilot light
Your selection will impact other settings.
Version
AF 11
AF 21
AF 22
AF 111
AF 190
AF 121
AF 122
AF 211
AF 221
AF 222
AF 901
Sight
Laser pilot light
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PA 41 AF 11
Version
CellaTemp PA 41 AF 21
Version
CellaTemp PA 41 AF 22
Version
CellaTemp PA 41 AF 111
Version
CellaTemp PA 41 AF 190
Version
CellaTemp PA 41 AF 121
Version
CellaTemp PA 41 AF 122
Version
CellaTemp PA 41 AF 211
Version
CellaTemp PA 41 AF 221
Version
CellaTemp PA 41 AF 222
Version
CellaTemp PA 41 AF 901
Measuring range
800 - 2400 °C
Measuring range
800 - 2400 °C
Measuring range
800 - 2400 °C
Measuring range
900 - 3000 °C
Measuring range
900 - 3000 °C
Measuring range
900 - 3000 °C
Measuring range
900 - 3000 °C
Measuring range
700 - 1800 °C
Measuring range
700 - 1800 °C
Measuring range
700 - 1800 °C
Measuring range
1100 - 3000 °C
Focal range
0,2 m - ∞
Focal range
0,12 m - ∞
Focal range
0,033 - 0,045 m
Focal range
0,2 m - ∞
Focal range
1,8 m
Focal range
0,12 m - ∞
Focal range
0,033 - 0,045 m
Focal range
0,2 m - ∞
Focal range
0,12 m - ∞
Focal range
0,033 - 0,045 m
Focal range
0,5 m - ∞
Shape of the measuring field
round
Distance ratio
190 : 1
Distance ratio
100 : 1
Distance ratio
50 : 1
Distance ratio
190 : 1
Distance ratio
175 : 1
Distance ratio
100 : 1
Distance ratio
50 : 1
Distance ratio
110 : 1
Distance ratio
50 : 1
Distance ratio
36 : 1
Distance ratio
340 : 1
Measuring head
PA 41.01
Measuring head
PA 41.05
Measuring head
PZ 41.18
Measuring head
PA 41.01
Measuring head
PA 41.03
Measuring head
PA 41.05
Measuring head
PZ 41.18
Measuring head
PA 41.01
Measuring head
PA 41.05
Measuring head
PZ 41.18
Measuring head
PA 41.02
Measuring principle
one-color
Sighting option
Laser pilot light
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaTemp PA 41
Technical Data
Measurement parameters
Measuring range
700 - 3,000 °C in sub-ranges
Sensor
Double photodiode
Spectral range
0.95 / 1.05 µm
Response time t98
Measuring range 800 - 2,400 °C:
≤ 20 ms (T > 950 °C)
Measuring range 900 - 3,000 °C:
≤ 20 ms (T > 1,050 °C)
Measuring range 700 - 1,800 °C:
≤ 20 ms (T > 850 °C)
Measuring range 1,100 - 3,000 °C:
≤ 20 ms (T > 1,350 °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Measuring heads
Measuring range 800 - 2,400 °C, 900 - 3,000 °C and 700 - 1,800 °C:
PA 41.01 (M30): focusing 0.2 m - ∞
PA 41.05 (M16): focusing 0.12 m - ∞
PZ 41.18 (M16): focusing 0.033 - 0.045 m
additionally for measuring range 800 - 2,400 °C:
PZ 41.05 (M30): Fokussierung 0,3 m - ∞
Measuring range 1,100 - 1,300 °C:
PA 41.02 (M16): focusing 0.5 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Analog input
0 - 10 V
Switching output
2 x Open Collector 24 V DC, ≤ 30 mA
Switching input
2 x to 24 V
Interface
USB
Interface
RS 485
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
Equipment
Sighting option
Laser pilot light
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 8-pin
Ambient temperature
Electronics: 0 - 65 °C
Measuring head: 250 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Electronics: Ø 65 mm x 187 mm
Measuring head: depending on the type
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Measuring range
Measured variable and scaling of analogue input and output signals
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Compensation of background radiation
Limit values and operating mode of the alarm contacts
Parameters of the ATD function (optional)
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°F
Measuring channel two-colour, one-colour 1 and one-colour 2
Threshold value of the contamination monitoring
Functions
Overtemperature signal
if the internal temperature exceeds 80 °C, the analog output shows a value > 20.5 mA
Service function
Simulation of a measured value or a current signal
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Measuring head
USB cable VK 11/D (1.8 m)
CellaView software
Operating manual (short)
* The fibre optic cable must be ordered separately.
Software
Software
CellaView
Pyrometer CellaTemp PA 41
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PA 41
Downloads
Brochure CellaTemp PA
Brochure CellaView
Manual CellaTemp PA 41
Declaration of conformity Declaration of Conformity PAxx
UKCA Declaration of Conformity PAxx
EAC Deklaration PK-PA-PT
X
Pyrometer CellaTemp PA 41
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Accessories for interfaces SU 02 AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Fan PB 08/F AF 3
On Request
Fiber optic cable LWL (10HT) 200µm
On Request
Fiber optic cable LWL (20HT) 200µm
On Request
Fiber optic cable LWL (25HT) 200µm
On Request
Fiber optic cable LWL (2HT) 200µm
On Request
Fiber optic cable LWL (5HT) 200µm
On Request
Fiber optic measuring head PA 41.01
On Request
Fiber optic measuring head PA 41.02
On Request
Fiber optic measuring head PZ 41.18
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
Junction box VK 30.02
On Request
Junction box VK 30.07
On Request
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PA 20-071
On Request
Mounting combinations PA 21-001
On Request
Mounting combinations PZ 41-003
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quartz window with hinge PZ 20/I AF 1
On Request
Quick coupling PA 20/D
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Pyrometer CellaTemp PA 41
IO-Link IODD
Pyrometer CellaTemp PA 41
IO-Link Manufacturer declaration
Pyrometer CellaTemp PA 41
Measurement field calculator
Pyrometer
PA 41 AF 11
(0,2 m - ∞)
PA 41 AF 111
(0,2 m - ∞)
PA 41 AF 121
(0,12 m - ∞)
PA 41 AF 122
(0,033 - 0,045 m)
PA 41 AF 190
(1,8 m)
PA 41 AF 21
(0,12 m - ∞)
PA 41 AF 211
(0,2 m - ∞)
PA 41 AF 22
(0,033 - 0,045 m)
PA 41 AF 221
(0,12 m - ∞)
PA 41 AF 222
(0,033 - 0,045 m)
PA 41 AF 901
(0,5 m - ∞)
PA 41 AF 11
(0,2 m - ∞)
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
8
16
24
32
40
48
56
64
72
80
88
96
104
112
120
128
136
144
152
160
168
176
184
192
200
1.05 mm
Measuring distance
Measuring field diameter
0.00 mm
21.50 mm
8.00 mm
20.68 mm
16.00 mm
19.86 mm
24.00 mm
19.05 mm
32.00 mm
18.23 mm
40.00 mm
17.41 mm
48.00 mm
16.59 mm
56.00 mm
15.77 mm
64.00 mm
14.96 mm
72.00 mm
14.14 mm
80.00 mm
13.32 mm
88.00 mm
12.50 mm
96.00 mm
11.69 mm
104.00 mm
10.87 mm
112.00 mm
10.05 mm
120.00 mm
9.23 mm
128.00 mm
8.41 mm
136.00 mm
7.60 mm
144.00 mm
6.78 mm
152.00 mm
5.96 mm
160.00 mm
5.14 mm
168.00 mm
4.32 mm
176.00 mm
3.51 mm
184.00 mm
2.69 mm
192.00 mm
1.87 mm
200.00 mm
1.05 mm