Pyrometer
Product finder
Pyrometer CellaTemp PK 21
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PK 21
Article description
The CellaTemp® PK 21 is a pyrometer for fast, non-contact and wear-free temperature measurement from a safe distance in the temperature range between 250 and 1,600 °C.
Special features:
Measuring range 250 to 1
600 °C -- switching output universally configurable -- high optical resolution due to precision lenses -- IO-Link interface -- all parameters can be set via pushbutton on the sensor or via interface from the plant control system -- test function can be triggered by pushbutton or control signal -- very simple mounting via M30 central thread-- large and bright LED display
Pyrometer CellaTemp PK 21
Properties
Version
Measuring range
250 - 1600 °C
250 - 1600 °C
Focal range
1,5 m
1,5 m
Your selection will impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PK 21 AF 1
Measuring range
250 - 1600 °C
Measuring field
10 mm
Focal range
1,5 m
Shape of the measuring field
round
Measuring principle
one-color
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PK 21
Technical Data
Measurement parameters
Measuring range
250 - 1600 °C
Sensor
Photodiode
Spectral range
1.0 - 1.7 µm
Response time t90
≤ 2 ms (T > 600 °C)
Measurement uncertainty
0.3 % of temp. reading [°C] plus 2.5 K
Repeatability
1 K
Temperature coefficient
0.07 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
Equipment
Display
4 x 7 segments LED red, digit height 8 mm
Status display
2 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin (A coded)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 210 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Damping time constant
Holding time of the peak picker
Operating mode and switching points of the switching contact
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Simulation of temperature
Test function
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Test function
via pushbutton or test input
Service function
Simulation of a measured value
Diagnostic function
Reverse polarity, overload and incorrect supply voltage indication
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrared thermometer CellaTemp PK
Operating manual (short)
2 fastening nuts
Pyrometer CellaTemp PK 21
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PK 21
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaTemp PKx IO-Link
Quick guide CellaTemp PKxx IO-Link
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Pyrometer CellaTemp PK 21
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bayonet coupling PS 11/N AF 4
On Request
Bayonet coupling PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Cooling jacket PK 01/B AF 1
On Request
Cooling jacket PK 01/C AF 1
On Request
Cooling jacket PK 01/C AF 2
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Digital display DA 230A
On Request
Dust stop ZA 01/C
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.02
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting combinations PK 01-006
On Request
Mounting combinations PK 01-007
On Request
Mounting combinations PK 01-011
On Request
Mounting combinations PK 01-014
On Request
Mounting combinations PK 01-022
On Request
Mounting combinations PK 01-023
On Request
Mounting combinations PK 01-024
On Request
Mounting combinations PK 01-027
On Request
Mounting combinations PK 01-028
On Request
Mounting combinations PK 01-029
On Request
Mounting combinations PK 11-001
On Request
Mounting combinations PK 11-006
On Request
Mounting combinations PK 11-008
On Request
Mounting combinations PK 21-001
On Request
Mounting combinations PK 21-002
On Request
Mounting combinations PK 21-004
On Request
Mounting combinations PK 21-005
On Request
Mounting combinations PK 21-006
On Request
Mounting combinations PK 21-007
On Request
Mounting combinations PK 21-008
On Request
Mounting combinations PK 21-009
On Request
Mounting combinations PK 21-012
On Request
Mounting flange Flansch DN 50 - R1.1/4"
On Request
Plate ZA 01/S
On Request
Plate ZA 01/W
On Request
Quartz window PS 01/I AF 2
On Request
Sapphire protective window PS 15/I AF 1
On Request
Supplementary lens PK 21/E AF 2
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Thermal insulating tube PS 01/K
On Request
Tube cap ZA 01/A
On Request
Pyrometer CellaTemp PK 21
IO-Link IODD
Type
Datei
Dateigröße
IODD PK21AF1_20221222.zip
383 KB
Download
Pyrometer CellaTemp PK 21
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PK 21 AF 1_202302_en.pdf
99 KB
Download
Pyrometer CellaTemp PK 21
Measurement field calculator
Pyrometer
PK 21 AF 1
(1,5 m)
PK 21 AF 1
(1,5 m)
Supplementary lens
none
PK 21/E
(0,5 m)
none
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
120
240
360
480
600
720
840
960
1080
1200
1320
1440
10.00 mm
Measuring distance
Measuring field diameter
0.00 mm
11.50 mm
60.00 mm
11.44 mm
120.00 mm
11.38 mm
180.00 mm
11.32 mm
240.00 mm
11.26 mm
300.00 mm
11.20 mm
360.00 mm
11.14 mm
420.00 mm
11.08 mm
480.00 mm
11.02 mm
540.00 mm
10.96 mm
600.00 mm
10.90 mm
660.00 mm
10.84 mm
720.00 mm
10.78 mm
780.00 mm
10.72 mm
840.00 mm
10.66 mm
900.00 mm
10.60 mm
960.00 mm
10.54 mm
1,020.00 mm
10.48 mm
1,080.00 mm
10.42 mm
1,140.00 mm
10.36 mm
1,200.00 mm
10.30 mm
1,260.00 mm
10.24 mm
1,320.00 mm
10.18 mm
1,380.00 mm
10.12 mm
1,440.00 mm
10.06 mm
1,500.00 mm
10.00 mm