Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PK 29
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
Product Data Sheets
FAQs
Warranty Information
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaTemp PK 29
Description
The CellaTemp® PK 29 is equipped with a special blocking filter. As a result, the measurement is not affected by daylight. This pyrometer also responds substantially less sensitive on reflective external radiation from hot objects around than conventional devices working at short wavelengths. This means that the CellaTemp® PK 29 can be used for a wide variety of applications in the metalworking industry and in particular for measuring the temperature of aluminium and bare metals at low temperatures. Due to the blocking filter, it can also be used for measurements in processes in which diode, Nd:YAG or CO2 lasers are used for heating. The energetically high laser radiation does not influence the measurement.
Special features:
Measuring range 150 to 800 °C
switching output universally configurable
high optical resolution due to precision lenses
IO-Link interface
all parameters can be set via pushbutton on the sensor or via interface from the plant control system
test function can be triggered by pushbutton or control signal
very simple mounting via M30 central thread
large and bright LED display
Pyrometer CellaTemp PK 29
Properties
Version
Measuring range
150 - 800 °C
150 - 800 °C
Focal distance
0,3 m
0,3 m
Your selection impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PK 29 AF 1
Measuring range
150 - 800 °C
Focal distance
0,3 m
Shape of the measurement area
round
Measuring principle
one-colour
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Pyrometer CellaTemp PK 29
Technical Data
Measurement parameters
Response time t90
≤ 2 ms (T > 300 °C)
≤ 15 ms (T > 200 °C)
≤ 45 ms (T > 150 °C)
Electrical parameters
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Functions
Test function
via button or test input
Diagnostic function
Indicates in case of reverse polarity, overload and wrong supply voltage
Reverse polarity protection
for power supply, analog output and switching output
Pyrometer CellaTemp PK 29
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PK 29
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaTemp PKx IO-Link
Quick guide CellaTemp PKxx IO-Link
Declaration of conformity Declaration of Conformity PKxy
UKCA Declaration of Conformity PKxy
EAC Deklaration PK-PA-PT
X
Pyrometer CellaTemp PK 29
Accessories
Software
Electrical accessories
Mechanical accessories
Mountings
Air purge PS 01/A AF 1
On Request
Air purge PS 01/A AF 2
On Request
Bajonettverschluss PS 11/N AF 4
On Request
Bajonettverschluss PS 11/N AF 5
On Request
Cable VK 02/L AF 1
On Request
Cable VK 02/L AF 2
On Request
Cable VK 02/L AF 3
On Request
Cable VK 02/O
On Request
Cable VK 02/R AF 1
On Request
Cable VK 03/A AF 1
On Request
Cable VK 03/A AF 2
On Request
Cable VK 03/H
On Request
Clamp ZA 01/E
On Request
Clamp ZA 01/T
On Request
Clamping collar PS 11/K AF 2
On Request
Clamping collar PS 11/K-35 AF 2
On Request
Clamping shaft ZA 01/D
On Request
Cooling jacket PK 01/B AF 1
On Request
Cooling jacket PK 01/C AF 1
On Request
Cooling jacket PK 01/C AF 2
On Request
Deflection mirror PS 01/R
On Request
Deflection mirror PS 11/W AF 1
On Request
Digital display DA 230A
On Request
Digital display DA 570
On Request
Dust stop ZA 01/C
On Request
Flange Flansch DN 50 - R1.1/4"
On Request
Flange PS 01/N
On Request
Flange ZA 01/I
On Request
Intermediate tube ZA 01/B
On Request
Intermediate tube ZA 01/M
On Request
IO-Link Software SW 50 AF 1
Junction box VK 30.02
On Request
Mounting bracket PS 11/P AF 1
On Request
Mounting bracket set PS 11/U
On Request
Mounting PK 01-006
On Request
Mounting PK 01-007
On Request
Mounting PK 01-011
On Request
Mounting PK 01-014
On Request
Mounting PK 01-022
On Request
Mounting PK 01-023
On Request
Mounting PK 01-024
On Request
Mounting PK 01-027
On Request
Mounting PK 01-028
On Request
Mounting PK 01-029
On Request
Mounting PK 01-032
On Request
Mounting PK 11-001
On Request
Mounting PK 11-006
On Request
Mounting PK 21-001
On Request
Mounting PK 21-002
On Request
Mounting PK 21-003
On Request
Mounting PK 21-004
On Request
Mounting PK 21-005
On Request
Mounting PK 21-006
On Request
Mounting PK 21-007
On Request
Mounting PK 21-008
On Request
Mounting PK 21-009
On Request
Mounting PK 21-012
On Request
Plate ZA 01/S
On Request
Plate ZA 01/U
On Request
Plate ZA 01/W
On Request
Quartz window PS 01/I AF 2
On Request
Sapphire window PS 15/I AF 1
On Request
Steckernetzteil E2EFSW3 12W-24V
On Request
Supplementary tube ZA 01/Q AF 2
On Request
Supplementary tube ZA 01/Q AF 3
On Request
Supplementary tube ZA 01/Q-35 AF 1
On Request
Thermal insulating tube PS 01/K
On Request
Tube cap ZA 01/A
On Request
Universal-Regler URE 422 RA
On Request
Zubehör PK PK 01/D
On Request
Pyrometer CellaTemp PK 29
IO-Link IODD
Type
Datei
Dateigröße
IODD PK29AF1_20221222.zip
383 KB
Download
Pyrometer CellaTemp PK 29
IO-Link Manufacturer explanation
Type
Datei
Dateigröße
MC PK 29 AF 1_202302_en.pdf
100 KB
Download
Pyrometer CellaTemp PK 29
Field-of-view calculator
Pyrometer
PK 29 AF 1
(0,3 m)
PK 29 AF 1
(0,3 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
7.00 mm
Measuring distance
Spot diameter
0.00 mm
21.40 mm
12.00 mm
20.82 mm
24.00 mm
20.25 mm
36.00 mm
19.67 mm
48.00 mm
19.10 mm
60.00 mm
18.52 mm
72.00 mm
17.94 mm
84.00 mm
17.37 mm
96.00 mm
16.79 mm
108.00 mm
16.22 mm
120.00 mm
15.64 mm
132.00 mm
15.06 mm
144.00 mm
14.49 mm
156.00 mm
13.91 mm
168.00 mm
13.34 mm
180.00 mm
12.76 mm
192.00 mm
12.18 mm
204.00 mm
11.61 mm
216.00 mm
11.03 mm
228.00 mm
10.46 mm
240.00 mm
9.88 mm
252.00 mm
9.30 mm
264.00 mm
8.73 mm
276.00 mm
8.15 mm
288.00 mm
7.58 mm
300.00 mm
7.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2023 –
Internetagentur
– Wrocklage Werbewerkstatt