Start page

Pyrometer CellaTemp PKF 66

Description

The CellaTemp® PKF 66 has separate electronics and measuring head. The infrared radiation is transmitted to the electronics via a fibre optic cable. The measuring head can be used without cooling in ambient temperatures up to 250 °C. This version can also be used in cramped mounting conditions or high electromagnetic fields. The length of the fibre optic cable can be up to 50 m.

Special features:
  • Measuring range 700 to 1,800 °C
  • fibre optic cable version up to 50 m length possible
  • switching output universally configurable
  • high optical resolution due to precision lenses
  • IO-Link interface
  • all parameters can be set via pushbutton on the sensor or via interface from the plant control system
  • test function can be triggered by pushbutton or control signal
  • very simple mounting via M30 central thread
  • large and bright LED display


Pyrometer CellaTemp PKF 66
Measuring range
Focal distance
Your selection impact other settings.
You can request this article from us
More information about IO-Link:

Version CellaTemp PKF 66 AF 1 
Version CellaTemp PKF 66 AF 2 
Version CellaTemp PKF 66 AF 3 
Version CellaTemp PKF 66 AF 4 
Version CellaTemp PKF 66 AF 5 
Measuring range 700 - 1800 °C 
Measuring range 700 - 1800 °C 
Measuring range 700 - 1800 °C 
Measuring range 700 - 1800 °C 
Measuring range 700 - 1800 °C 
Measuring field 6,9 mm 
Measuring field 8 mm 
Focal distance 0,2 m - ∞ 
Focal distance 1,08 m 
Focal distance 0,12 m - ∞ 
Focal distance 0,033 - 0,045 m 
Focal distance 1,8 m 
Shape of the measurement area round 
Distance ratio 190 : 1 
Distance ratio 100 : 1 
Distance ratio 50 : 1 
Measuring head PA 41.01 
Measuring head PKS 21.01 
Measuring head PA 41.05 
Measuring head PZ 41.18 
Measuring head PA 41.03 
Measuring principle one-colour 
Sighting option Laser pilot light 

INDICE 6 Login