Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PR 11
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PR 11
Article description
The CellaTemp® PR 11 is a smart infrared thermometer for fast, non-contact and wear-free temperature measurement from a safe distance in the temperature range between 0 and 1,000 °C.
Special features:
Compact infrared thermometer -- standardised PLC and fieldbus-independent IO-Link interface -- analogue output 0/4 - 20 mA -- large measuring ranges with high temperature resolution -- high optical resolution and measuring accuracy due to broadband anti-reflective precision lenses -- switching output universally configurable -- easy mounting via M30 central thread
Pyrometer CellaTemp PR 11
Properties
Version
Measuring range
0 - 1000 °C
0 - 1000 °C
Focal range
0,3 m
0,3 m
Your selection will impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PR 11 AF 1
Measuring range
0 - 1000 °C
Measuring field
11 mm
Focal range
0,3 m
Shape of the measuring field
round
Measuring principle
one-color
Technical Data
Downloads
Measurement field calculator
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PR 11
Technical Data
Measurement parameters
Measuring range
0 - 1000 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t90
≤ 60 ms
Measurement uncertainty
0.75 % of temp. reading [°C] plus 2.0 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
General parameters
Connection
M12 Schraubverbindung 4-polig (A codiert)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 30 x 185 mm (without plug)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Emissivity
Damping time constant
Holding time of the peak picker
Operating mode and switching points of the switching contact
Reset to factory setting
Temperature unit °C/°F
Simulation of temperature
Functions
Overtemperature signal
Signalisierung der Fehlercodes bzw. Ereignisse erfolgen
über die digitale Schnittstelle
Service function
Simulation of a measured value
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrarot-Thermometer CellaTemp PR
Operating manual (short)
2 fastening nuts
Pyrometer CellaTemp PR 11
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PR 11
Downloads
Brochure CellaTemp PR
Brochure Flyer IO-Link
Manual CellaTemp PR xx
Quick guide CellaTemp PRxx
Declaration of conformity Declaration of Conformity PRxx
UKCA Declaration of Conformity PRxx
X
Pyrometer CellaTemp PR 11
Accessories
Wir haben leider kein passendes Zubehör gefunden.
Pyrometer CellaTemp PR 11
IO-Link IODD
Type
Datei
Dateigröße
IODD PR11AF1_20200922.zip
266 KB
Download
Pyrometer CellaTemp PR 11
IO-Link Manufacturer declaration
Pyrometer CellaTemp PR 11
Measurement field calculator
Pyrometer
PR 11 AF 1
(0,3 m)
PR 11 AF 1
(0,3 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
11.00 mm
Measuring distance
Measuring field diameter
0.00 mm
16.50 mm
12.00 mm
16.28 mm
24.00 mm
16.06 mm
36.00 mm
15.84 mm
48.00 mm
15.62 mm
60.00 mm
15.40 mm
72.00 mm
15.18 mm
84.00 mm
14.96 mm
96.00 mm
14.74 mm
108.00 mm
14.52 mm
120.00 mm
14.30 mm
132.00 mm
14.08 mm
144.00 mm
13.86 mm
156.00 mm
13.64 mm
168.00 mm
13.42 mm
180.00 mm
13.20 mm
192.00 mm
12.98 mm
204.00 mm
12.76 mm
216.00 mm
12.54 mm
228.00 mm
12.32 mm
240.00 mm
12.10 mm
252.00 mm
11.88 mm
264.00 mm
11.66 mm
276.00 mm
11.44 mm
288.00 mm
11.22 mm
300.00 mm
11.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt