Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PR 18
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaTemp PR 18
Description
The CellaTemp® PR 18 has a special resistant lens. This allows its usage even in extreme environmental conditions, such as in asphalt and concrete mixing plants, without damaging the lens by aggressive vapours and dusts.
Special features:
Compact infrared thermometer
standardised PLC and fieldbus-independent IO-Link interface
analogue output 0/4 - 20 mA
large measuring ranges with high temperature resolution
high optical resolution and measuring accuracy due to broadband anti-reflective precision lenses
switching output universally configurable
easy mounting via M30 central thread
Pyrometer CellaTemp PR 18
Properties
Version
Measuring range
0 - 500 °C
0 - 500 °C
Focal distance
0,3 m
0,3 m
Your selection impact other settings.
Version
AF 1
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PR 18 AF 1
Measuring range
0 - 500 °C
Measuring field
11 mm
Focal distance
0,3 m
Shape of the measurement area
round
Measuring principle
one-colour
Technical Data
Downloads
Field-of-view calculator
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Pyrometer CellaTemp PR 18
Technical Data
Measurement parameters
Measuring range
0 - 500 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t90
≤ 60 ms
Measurement uncertainty
0.75 % of temp. reading [°C] plus 2.0 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output
0.2 K + 0.03 % of selected range
Resolution interface
0.1 K
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
General parameters
Connection
M12 Schraubverbindung 4-polig (A codiert)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 30 x 185 mm (without plug)
Housing
Stainless steel V2A (1.4305)
Protection class
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analog output
Emissivity
Damping time constant
Hold time of the maximum value memory
Operation mode and switching points of the switching contact
Reset to factory setting
Temperature unit °C/°F
Simulation of temperature
Functions
Overtemperature signal
Signalisierung der Fehlercodes bzw. Ereignisse erfolgen
über die digitale Schnittstelle
Service function
Simulation of a measured value
Reverse polarity protection
for power supply, analog output and switching output
Scope of delivery
Scope of delivery
Infrarot-Thermometer CellaTemp PR
Manual (short)
2 fixing nuts
Pyrometer CellaTemp PR 18
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PR 18
Downloads
Brochure CellaTemp PR
Brochure Flyer IO-Link
Manual CellaTemp PR xx
Quick guide CellaTemp PRxx
Declaration of conformity Declaration of Conformity PRxx
UKCA Declaration of Conformity PRxx
X
Pyrometer CellaTemp PR 18
Accessories
Wir haben leider kein passendes Zubehör gefunden.
Pyrometer CellaTemp PR 18
IO-Link IODD
Type
Datei
Dateigröße
IODD PR18AF1_20211007.zip
266 KB
Download
Pyrometer CellaTemp PR 18
IO-Link Manufacturer explanation
Pyrometer CellaTemp PR 18
Field-of-view calculator
Pyrometer
PR 18 AF 1
(0,3 m)
PR 18 AF 1
(0,3 m)
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
11.00 mm
Measuring distance
Spot diameter
0.00 mm
16.50 mm
12.00 mm
16.28 mm
24.00 mm
16.06 mm
36.00 mm
15.84 mm
48.00 mm
15.62 mm
60.00 mm
15.40 mm
72.00 mm
15.18 mm
84.00 mm
14.96 mm
96.00 mm
14.74 mm
108.00 mm
14.52 mm
120.00 mm
14.30 mm
132.00 mm
14.08 mm
144.00 mm
13.86 mm
156.00 mm
13.64 mm
168.00 mm
13.42 mm
180.00 mm
13.20 mm
192.00 mm
12.98 mm
204.00 mm
12.76 mm
216.00 mm
12.54 mm
228.00 mm
12.32 mm
240.00 mm
12.10 mm
252.00 mm
11.88 mm
264.00 mm
11.66 mm
276.00 mm
11.44 mm
288.00 mm
11.22 mm
300.00 mm
11.00 mm
Request a quote