Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PX 10
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PX 10
Article description
The CellaTemp® PX 10 is a digital pyrometer for measuring temperatures from 0 to 1,000 °C. Due to the very large measuring span, it can be used very universally for a variety of applications, primarily on non-metallic measuring objects. A through-the-lens sighting or a laser pilot light is available for easy and precise sighting of the measuring object. The LED display on the back can be read from a great distance. In normal operation, the current measuring temperature is displayed. If current parameters are changed via the rear buttons, the changed settings are shown on the display.
Special features:
Measuring range 0 to 1
000 °C -- modern IO-Link interface -- focusable interchangeable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lenses -- LED display can be read from a great distance -- all parameters and functions adjustable via keyboard -- test current output for the diagnostic function -- 1 analogue output and 2 switching outputs -- source freely configurable -- ATD function for automatic temperature detection
Pyrometer CellaTemp PX 10
Properties
Version
Measuring range
0 - 1000 °C
0 - 1000 °C
Focal range
0,15 - 0,3 m
0,15 - 0,3 m
0,3 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Laser pilot light
Video camera
Your selection will impact other settings.
Version
AF 1
AF 2
Sight
Through-the-lens sighting
Laser pilot light
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PX 10 AF 1
Version
CellaTemp PX 10 AF 2
Measuring range
0 - 1000 °C
Measuring range
0 - 1000 °C
Focal range
0,3 m - ∞
Focal range
0,15 - 0,3 m
Shape of the measuring field
round
Distance ratio
50 : 1
Distance ratio
48 : 1
Objective
PZ 10.01
Objective
PZ 10.05
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
Video camera
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PX 10
Technical Data
Measurement parameters
Measuring range
0 - 1000 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t98
≤ 30 ms
Measurement uncertainty
1 % of temp. reading [°C] min. 2 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Optical variants
Objective lenses
Standard objective lens PZ 10.01: focusing 0.3 m - ∞
Close-up lens PZ 10.05: focusing 0.15 m - 0.3 m
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
video camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
video camera
Display
4 x 7 segments LED red, digit height 8 mm
Status display
4 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Limit values and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
additionally for pyrometer with camera:
TBC funktion
White balance
Measuring point number
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
Operating manual (short)
Pyrometer CellaTemp PX 10
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PX 10
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Manual CellaTemp PX 1x 2x 3x
Quick guide CellaTemp PX 1x 2x 3x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaTemp PX 10
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Close-up optics PZ 10.05
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Dust stop PZ 10/S
On Request
Dust stop PZ 10/T
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.07
On Request
Monitor system 0
On Request
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PA 10-002
On Request
Mounting combinations PA 10-008
On Request
Mounting combinations PA 83-001
On Request
Mounting combinations PA 83-002
On Request
Mounting combinations PA 83-003
On Request
Mounting combinations PA 83-004
On Request
Mounting combinations PA 83-005
On Request
Mounting combinations PA 83-006
On Request
Mounting combinations PA 83-007
On Request
Mounting combinations PA 83-008
On Request
Mounting combinations PA 83-009
On Request
Mounting combinations PA 83-010
On Request
Mounting combinations PA 83-011
On Request
Mounting combinations PA 83-013
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Quick coupling PA10/C
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Standard optics PZ 10.01
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Vorsatzlinsen für PZ 10 PZ 10/A
On Request
ZnS disk hinge PZ 10/I AF 4
On Request
ZnS window PA 10/I
On Request
Pyrometer CellaTemp PX 10
IO-Link IODD
Type
Datei
Dateigröße
IODD PX10AF1-2-L_20180523.zip
1488 KB
Download
IODD PX10AF1-2-C_20181108.zip
1489 KB
Download
IODD PX10AF1-2_20180319.zip
1478 KB
Download
Pyrometer CellaTemp PX 10
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PX 10 AF 1 2 L_20181107_en.pdf
357 KB
Download
MC PX 10 AF 1 2 C_20181108_en.pdf
357 KB
Download
MC PX 10 AF 1 2_20181031_en.pdf
354 KB
Download
Pyrometer CellaTemp PX 10
Measurement field calculator
Pyrometer
PX 10 AF 1
(0,3 m - ∞)
PX 10 AF 2
(0,15 - 0,3 m)
PX 10 AF 1
(0,3 m - ∞)
Supplementary lens
none
PZ 10/A
(0,036 - 0,042 m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
6.00 mm
Measuring distance
Measuring field diameter
0.00 mm
24.00 mm
12.00 mm
23.28 mm
24.00 mm
22.56 mm
36.00 mm
21.84 mm
48.00 mm
21.12 mm
60.00 mm
20.40 mm
72.00 mm
19.68 mm
84.00 mm
18.96 mm
96.00 mm
18.24 mm
108.00 mm
17.52 mm
120.00 mm
16.80 mm
132.00 mm
16.08 mm
144.00 mm
15.36 mm
156.00 mm
14.64 mm
168.00 mm
13.92 mm
180.00 mm
13.20 mm
192.00 mm
12.48 mm
204.00 mm
11.76 mm
216.00 mm
11.04 mm
228.00 mm
10.32 mm
240.00 mm
9.60 mm
252.00 mm
8.88 mm
264.00 mm
8.16 mm
276.00 mm
7.44 mm
288.00 mm
6.72 mm
300.00 mm
6.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt