Start page
Search
Log in
Cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PX 15
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
Product Data Sheets
FAQs
Warranty Information
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaTemp PX 15
Description
In the range between 4.6 ,4.9 μm, glass has an emissivity of almost 100 %. Above 5 µm, atmospheric influences such as humidity or water vapour affect the measurement. The CellaTemp® PX 15 has a blocking filter with a spectral sensitivity of 4.6 ,4.9 µm. It thus detects the temperature from the area near the surface of the glass. Interferences such as thickness changes, different types of glass or humidity changes do not affect the measured value at this wavelength.
Special features:
Measuring range 300 to 2,500 °C
modern IO-Link interface
focusable interchangeable lenses for exact adjustment of the measuring distance
broadband anti-reflective precision lenses
LED display can be read from a great distance
all parameters and functions adjustable via keyboard
test current output for the diagnostic function
1 analogue output and 2 switching outputs
source freely configurable
ATD function for automatic temperature detection
Pyrometer CellaTemp PX 15
Properties
Version
Measuring range
300 -1300 °C
300 -1300 °C
500 - 2500 °C
Focal distance
0,8 m - ∞
0,8 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Laser pilot light
Video camera
Your selection impact other settings.
Version
AF 1
AF 2
Sighting option
Through-the-lens-sighting
Laser pilot light
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PX 15 AF 1
Version
CellaTemp PX 15 AF 2
Measuring range
500 - 2500 °C
Measuring range
300 -1300 °C
Focal distance
0,8 m - ∞
Focal distance
0,8 m - ∞
Shape of the measurement area
round
Distance ratio
70 : 1
Distance ratio
45 : 1
Objective
PZ 15.03
Objective
PZ 15.03
Measuring principle
one-colour
Sighting option
Through-the-lens-sighting
Sighting option
Laser pilot light
Sighting option
Video camera
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Pyrometer CellaTemp PX 15
Technical Data
Optical variants
Lenses
Standard-Objektiv PZ 15.03: Fokussierung 0,8 m - ∞
Camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Functions
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Pyrometer CellaTemp PX 15
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PX 15
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Quick guide CellaTemp PX 1x 2x 3x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaTemp PX 15
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mountings
Adapter flange PB 08/J AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminium compact hose PB 08/L
On Request
Ball and socket mounting PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
CaF2-Scheibenscharnier PZ 15/I AF 1
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Digital display DA 570
On Request
Dust stop PZ 10/S
On Request
Dust stop PZ 10/S AF 2
On Request
Emissivity switching box VK 30.07
On Request
Fan PB 08/F AF 3
On Request
Fan PB 08/F AF 4
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange PZ 20/F-120
On Request
Flange PZ 20/F-120 DN50
On Request
Flange PZ 20/F-130
On Request
Flange PZ 20/F-145
On Request
Flange PZ 20/F-160
On Request
Flange PZ 20/F-50
On Request
Flange PZ 40/D
On Request
Flange PZ 40/N-130 AF 1
On Request
Flange PZ 40/N-130 AF 2
On Request
Flange tube PB 08/M AF1
On Request
Flange ZA 10/F-160
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Interface isolator SU 07 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link Software SW 50 AF 1
Junction box VA 20.01
On Request
Junction box VK 30.04
On Request
Junction box VK 30.05
On Request
Lens system PZ 15.03
On Request
Material selector switch VK 30.01
On Request
Monitor system 0
On Request
Mounting angle PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting PA 83-001
On Request
Mounting PA 83-002
On Request
Mounting PA 83-003
On Request
Mounting PA 83-004
On Request
Mounting PA 83-005
On Request
Mounting PA 83-006
On Request
Mounting PA 83-007
On Request
Mounting PA 83-008
On Request
Mounting PA 83-009
On Request
Mounting PA 83-010
On Request
Mounting PA 83-011
On Request
Mounting PA 83-013
On Request
Mounting PA 90-001
On Request
Mounting PB 08/K AF 2
On Request
Mounting PB 08/Q AF 1
On Request
Mounting socket PZ 20/G AF 1
On Request
Oscillating mirror PZ 20/X AF 5
On Request
Oscillating mirror PZ 20/X AF 6
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Quick coupling PA15/C
On Request
Sapphire window PA 15/I
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Spherical flange PB 08/I AF 3
On Request
Spherical flange PB 08/I AF 4
On Request
Steckernetzteil E2EFSW3 12W-24V
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Universal-Regler URE 422 RA
On Request
Video encoder SU 08 AF 1
On Request
Videokabel VK 02/F AF 1
On Request
Videokabel VK 02/F AF 2
On Request
Videokabel VK 02/F AF 3
On Request
Vorsatzlinsen für PA 15 PA 15/A
On Request
Pyrometer CellaTemp PX 15
IO-Link IODD
Type
Datei
Dateigröße
IODD PX15AF1-L_20190318.zip
1743 KB
Download
IODD PX15AF2-C_20190321.zip
1742 KB
Download
IODD PX15AF2_20190321.zip
1729 KB
Download
IODD PX15AF1_20190318.zip
1729 KB
Download
IODD PX15AF1-C_20190318.zip
1739 KB
Download
IODD PX15AF2-L_20190321.zip
1739 KB
Download
Pyrometer CellaTemp PX 15
IO-Link Manufacturer explanation
Type
Datei
Dateigröße
MC PX 15 AF 2 C_20190321_en.pdf
355 KB
Download
MC PX 15 AF 1 C_20190319_en.pdf
352 KB
Download
MC PX 15 AF 1_20190319_en.pdf
352 KB
Download
MC PX 15 AF 2_20190321_en.pdf
352 KB
Download
MC PX 15 AF 1 L_20190319_en.pdf
352 KB
Download
MC PX 15 AF 2 L_20190321_en.pdf
354 KB
Download
Pyrometer CellaTemp PX 15
Field-of-view calculator
Pyrometer
PX 15 AF 1
(0,8 m - ∞)
PX 15 AF 2
(0,8 m - ∞)
PX 15 AF 1
(0,8 m - ∞)
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
64
128
192
256
320
384
448
512
576
640
704
768
11.43 mm
Measuring distance
Spot diameter
0.00 mm
24.00 mm
32.00 mm
23.50 mm
64.00 mm
22.99 mm
96.00 mm
22.49 mm
128.00 mm
21.99 mm
160.00 mm
21.49 mm
192.00 mm
20.98 mm
224.00 mm
20.48 mm
256.00 mm
19.98 mm
288.00 mm
19.47 mm
320.00 mm
18.97 mm
352.00 mm
18.47 mm
384.00 mm
17.97 mm
416.00 mm
17.46 mm
448.00 mm
16.96 mm
480.00 mm
16.46 mm
512.00 mm
15.95 mm
544.00 mm
15.45 mm
576.00 mm
14.95 mm
608.00 mm
14.45 mm
640.00 mm
13.94 mm
672.00 mm
13.44 mm
704.00 mm
12.94 mm
736.00 mm
12.43 mm
768.00 mm
11.93 mm
800.00 mm
11.43 mm