Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PX 15
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PX 15
Article description
In the range between 4.6 ,4.9 μm, glass has an emissivity of almost 100 %. Above 5 µm, atmospheric influences such as humidity or water vapour affect the measurement. The CellaTemp® PX 15 has a blocking filter with a spectral sensitivity of 4.6 ,4.9 µm. It thus detects the temperature from the area near the surface of the glass. Interferences such as thickness changes, different types of glass or humidity changes do not affect the measured value at this wavelength.
Special features:
Measuring range 300 to 2
500 °C -- modern IO-Link interface -- focusable interchangeable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lenses -- LED display can be read from a great distance -- all parameters and functions adjustable via keyboard -- test current output for the diagnostic function -- 1 analogue output and 2 switching outputs -- source freely configurable -- ATD function for automatic temperature detection
Pyrometer CellaTemp PX 15
Properties
Version
Measuring range
300 -1300 °C
300 -1300 °C
500 - 2500 °C
Focal range
0,8 m - ∞
0,8 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Laser pilot light
Video camera
Your selection will impact other settings.
Version
AF 1
AF 2
Sight
Through-the-lens sighting
Laser pilot light
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PX 15 AF 1
Version
CellaTemp PX 15 AF 2
Measuring range
500 - 2500 °C
Measuring range
300 -1300 °C
Focal range
0,8 m - ∞
Focal range
0,8 m - ∞
Shape of the measuring field
round
Distance ratio
70 : 1
Distance ratio
45 : 1
Objective
PZ 15.03
Objective
PZ 15.03
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
Video camera
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PX 15
Technical Data
Measurement parameters
Measuring range
300 - 2,500 °C in sub-ranges
Sensor
Thermopile
Spectral range
4.6 - 4.9 µm
Response time t98
≤ 100 ms
Measurement uncertainty
0.75 % of temp. reading [°C] min. 3 K
Repeatability
2 K
Temperature coefficient
0.04 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Objective lenses
Standard-Objektiv PZ 15.03: Fokussierung 0,8 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
video camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
video camera
Display
4 x 7 segments LED red, digit height 8 mm
Status display
4 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Limit values and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
additionally for pyrometer with camera:
TBC funktion
White balance
Measuring point number
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
Operating manual (short)
Pyrometer CellaTemp PX 15
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PX 15
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Manual CellaTemp PX 1x 2x 3x
Quick guide CellaTemp PX 1x 2x 3x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaTemp PX 15
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
CaF2 disk hinge PZ 15/I AF 1
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Dust stop PZ 10/S
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.07
On Request
Lens PZ 15.03
On Request
Monitor system 0
On Request
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PA 83-001
On Request
Mounting combinations PA 83-002
On Request
Mounting combinations PA 83-003
On Request
Mounting combinations PA 83-004
On Request
Mounting combinations PA 83-005
On Request
Mounting combinations PA 83-006
On Request
Mounting combinations PA 83-007
On Request
Mounting combinations PA 83-008
On Request
Mounting combinations PA 83-009
On Request
Mounting combinations PA 83-010
On Request
Mounting combinations PA 83-011
On Request
Mounting combinations PA 83-013
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Quick coupling PA15/C
On Request
Sapphire protective window PA 15/I
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Vorsatzlinsen für PA 15 PA 15/A
On Request
Pyrometer CellaTemp PX 15
IO-Link IODD
Type
Datei
Dateigröße
IODD PX15AF1_20190318.zip
1729 KB
Download
IODD PX15AF2-L_20190321.zip
1739 KB
Download
IODD PX15AF2-C_20190321.zip
1742 KB
Download
IODD PX15AF2_20190321.zip
1729 KB
Download
IODD PX15AF1-C_20190318.zip
1739 KB
Download
IODD PX15AF1-L_20190318.zip
1743 KB
Download
Pyrometer CellaTemp PX 15
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PX 15 AF 2 L_20190321_en.pdf
354 KB
Download
MC PX 15 AF 1 L_20190319_en.pdf
352 KB
Download
MC PX 15 AF 1 C_20190319_en.pdf
352 KB
Download
MC PX 15 AF 2_20190321_en.pdf
352 KB
Download
MC PX 15 AF 2 C_20190321_en.pdf
355 KB
Download
MC PX 15 AF 1_20190319_en.pdf
352 KB
Download
Pyrometer CellaTemp PX 15
Measurement field calculator
Pyrometer
PX 15 AF 1
(0,8 m - ∞)
PX 15 AF 2
(0,8 m - ∞)
PX 15 AF 1
(0,8 m - ∞)
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
64
128
192
256
320
384
448
512
576
640
704
768
11.43 mm
Measuring distance
Measuring field diameter
0.00 mm
24.00 mm
32.00 mm
23.50 mm
64.00 mm
22.99 mm
96.00 mm
22.49 mm
128.00 mm
21.99 mm
160.00 mm
21.49 mm
192.00 mm
20.98 mm
224.00 mm
20.48 mm
256.00 mm
19.98 mm
288.00 mm
19.47 mm
320.00 mm
18.97 mm
352.00 mm
18.47 mm
384.00 mm
17.97 mm
416.00 mm
17.46 mm
448.00 mm
16.96 mm
480.00 mm
16.46 mm
512.00 mm
15.95 mm
544.00 mm
15.45 mm
576.00 mm
14.95 mm
608.00 mm
14.45 mm
640.00 mm
13.94 mm
672.00 mm
13.44 mm
704.00 mm
12.94 mm
736.00 mm
12.43 mm
768.00 mm
11.93 mm
800.00 mm
11.43 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt