Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PX 35
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PX 35
Article description
The CellaTemp® PX 35 has a very short-wave and narrow-band spectral sensitivity. Therefore, the pyrometer reacts to interfering influences such as signal weakening by dust, vapour or smoke in the pyrometer's field of view, to soiling of the protective window or to emissivity fluctuations of the measuring object much less than a conventional spectral pyrometer. Metals have the physical property that the emissivity increases with shorter radiation wavelengths and higher object temperatures. Therefore, the CellaTemp® PX 35 is ideal for precise measurement of metals and very hot objects. In addition, the pyrometer is used to measure thin semiconductors, as semiconductors have very good radiation properties in the pyrometer's special spectral range. For wavelengths > 1 µm, silicon is transparent, so a standard pyrometer would measure the temperature of the material behind it through the silicon.
Special features:
Pyrometer CellaTemp PX 35
Properties
Version
Measuring range
600 - 3000 °C
600 - 3000 °C
Focal range
0,2 - 0,4 m
0,2 - 0,4 m
0,2 m - ∞
0,4 m - ∞
0,6 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Laser pilot light
Video camera
Your selection will impact other settings.
Version
AF 1
AF 2
AF 3
AF 4
AF 5
Sight
Through-the-lens sighting
Laser pilot light
Video camera
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PX 35 AF 1
Version
CellaTemp PX 35 AF 2
Version
CellaTemp PX 35 AF 3
Version
CellaTemp PX 35 AF 4
Version
CellaTemp PX 35 AF 5
Measuring range
600 - 3000 °C
Measuring range
600 - 3000 °C
Measuring range
600 - 3000 °C
Measuring range
600 - 3000 °C
Measuring range
600 - 3000 °C
Focal range
0,4 m - ∞
Focal range
0,2 - 0,4 m
Focal range
1,2 m - ∞
Focal range
0,2 m - ∞
Focal range
0,6 m - ∞
Shape of the measuring field
round
Distance ratio
210 : 1
Distance ratio
200 : 1
Distance ratio
310 : 1
Distance ratio
55 : 1
Distance ratio
430 : 1
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Objective
PZ 20.05
Objective
PA 20.06
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
Video camera
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PX 35
Technical Data
Measurement parameters
Measuring range
600 - 3000 °C
Sensor
Photodiode
Spectral range
0.82 - 0.93 µm
Response time t98
≤ 50 ms (T > 650 °C)
≤ 2 ms (T > 850 °C)
Measurement uncertainty
0.3 % of temp. reading [°C] min. 4 K
Repeatability
1 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Objective lenses
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens I PZ 20.06: focusing 1.2 m - ∞
Telephoto lens II PA 20.06: focusing 0.6 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
video camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
Sighting option
video camera
Display
4 x 7 segments LED red, digit height 8 mm
Status display
4 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Limit values and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
additionally for pyrometer with camera:
TBC funktion
White balance
Measuring point number
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
ATD (Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
Operating manual (short)
Pyrometer CellaTemp PX 35
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PX 35
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Brochure Supplementary lenses
Manual CellaTemp PX 1x 2x 3x
Quick guide CellaTemp PX 1x 2x 3x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaTemp PX 35
Accessories
Software
Electrical accessories
Optical accessories
Mechanical accessories
Mounting solutions
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Close-up optics PZ 20.03
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Dust stop PZ 20/S
On Request
Dust stop PZ 20/T
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link software SW 50 AF 1
Junction box VK 30.07
On Request
Lens PZ 20.08
On Request
Monitor system 0
On Request
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PA 20-005
On Request
Mounting combinations PA 20-006
On Request
Mounting combinations PA 20-007
On Request
Mounting combinations PA 20-008
On Request
Mounting combinations PA 20-009
On Request
Mounting combinations PA 20-010
On Request
Mounting combinations PA 20-012
On Request
Mounting combinations PA 20-014
On Request
Mounting combinations PA 20-015
On Request
Mounting combinations PA 20-024
On Request
Mounting combinations PA 20-027
On Request
Mounting combinations PA 20-028
On Request
Mounting combinations PA 20-036
On Request
Mounting combinations PA 20-037
On Request
Mounting combinations PA 20-048
On Request
Mounting combinations PA 20-052
On Request
Mounting combinations PA 20-054
On Request
Mounting combinations PA 20-058
On Request
Mounting combinations PA 20-059
On Request
Mounting combinations PA 20-060
On Request
Mounting combinations PA 20-062
On Request
Mounting combinations PA 20-064
On Request
Mounting combinations PA 20-065
On Request
Mounting combinations PA 20-066
On Request
Mounting combinations PA 20-073
On Request
Mounting combinations PA 20-077
On Request
Mounting combinations PA 20-080
On Request
Mounting combinations PA 20-081
On Request
Mounting combinations PA 20-091
On Request
Mounting combinations PA 20-098
On Request
Mounting combinations PA 20-100
On Request
Mounting combinations PA 20-103
On Request
Mounting combinations PA 20-107
On Request
Mounting combinations PA 20-112
On Request
Mounting combinations PA 20-117
On Request
Mounting combinations PA 20-122
On Request
Mounting combinations PA 83-001
On Request
Mounting combinations PA 83-002
On Request
Mounting combinations PA 83-003
On Request
Mounting combinations PA 83-004
On Request
Mounting combinations PA 83-005
On Request
Mounting combinations PA 83-006
On Request
Mounting combinations PA 83-007
On Request
Mounting combinations PA 83-008
On Request
Mounting combinations PA 83-009
On Request
Mounting combinations PA 83-010
On Request
Mounting combinations PA 83-011
On Request
Mounting combinations PA 83-012
On Request
Mounting combinations PA 83-013
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quartz protective window 70146
On Request
Quartz window PA 20/I
On Request
Quartz window with hinge PZ 20/I AF 1
On Request
Quick coupling PA 20/C
On Request
Quick coupling PA 20/D
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Standard optics PZ 20.01
On Request
Supplementary lens PZ 20/O-120
On Request
Supplementary lens PZ 20/O-75
On Request
Tele-optics PA 20.06
On Request
Tele-optics PZ 20.06
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-50
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-63
On Request
Wide-angle optics PZ 20.05
On Request
Pyrometer CellaTemp PX 35
IO-Link IODD
Type
Datei
Dateigröße
IODD PX35AF1-2-3-4-5-L_20190503.zip
1740 KB
Download
IODD PX35AF1-2-3-4-5-C_20190109.zip
1486 KB
Download
IODD PX35AF1-2-3-4-5_20190109.zip
1481 KB
Download
Pyrometer CellaTemp PX 35
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PX 35 AF 1 2 3 4 5_20190110_en.pdf
366 KB
Download
MC PX 35 AF 1 2 3 4 5 C_20190110_en.pdf
366 KB
Download
MC PX 35 AF 1 2 3 4 5 L_20190111_en.pdf
364 KB
Download
Pyrometer CellaTemp PX 35
Measurement field calculator
Pyrometer
PX 35 AF 1
(0,4 m - ∞)
PX 35 AF 2
(0,2 - 0,4 m)
PX 35 AF 3
(1,2 m - ∞)
PX 35 AF 4
(0,2 m - ∞)
PX 35 AF 5
(0,6 m - ∞)
PX 35 AF 1
(0,4 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,036 - 0,041 m)
PZ 20/O-63
(0,045 - 0,054 m)
PZ 20/O-75
(0,052 - 0,063 m)
PZ 20/O-120
(0,084 - 0,112 m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
1.90 mm
Measuring distance
Measuring field diameter
0.00 mm
18.00 mm
16.00 mm
17.36 mm
32.00 mm
16.71 mm
48.00 mm
16.07 mm
64.00 mm
15.42 mm
80.00 mm
14.78 mm
96.00 mm
14.14 mm
112.00 mm
13.49 mm
128.00 mm
12.85 mm
144.00 mm
12.21 mm
160.00 mm
11.56 mm
176.00 mm
10.92 mm
192.00 mm
10.27 mm
208.00 mm
9.63 mm
224.00 mm
8.99 mm
240.00 mm
8.34 mm
256.00 mm
7.70 mm
272.00 mm
7.06 mm
288.00 mm
6.41 mm
304.00 mm
5.77 mm
320.00 mm
5.12 mm
336.00 mm
4.48 mm
352.00 mm
3.84 mm
368.00 mm
3.19 mm
384.00 mm
2.55 mm
400.00 mm
1.90 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt