Start page
Media library
watch list
Contact
Search
Log in
Shopping cart
Search results
Log in
User name/email
Password
Log in
Menu
Pyrometers
Product finder
Pyrometer CellaTemp PX 61
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Pyrometers
Pyrometers
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
Application solutions
Contact
Contact
Support
FAQs
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
IO-Link
Pyrometer CellaTemp PX 61
Article description
The CellaTemp® PX 61 is a digital two-colour pyrometer with a fibre optic cable for measuring temperatures between 375 and 1,200 °C. The two-colour pyrometer is equipped with a separate optical measuring head and a fibre optic cable. The fibre optic cable and measuring head are insensitive to interference from electromagnetic radiation and can be used in ambient temperatures up to 250 °C without cooling. The variant with separate optical measuring head has advantages especially in confined spaces.
Special features:
Measuring range 375 to 1
200 °C -- focusable interchangeable lenses for exact adjustment of the measuring distance -- broadband anti-reflective precision lenses -- short measuring wavelengths -- LED display can be read from a great distance -- test current output for the diagnostic function -- standard feature: analogue output and USB/RS 485 interface -- measuring head and fibre optic cable heat resistant up to 250 °C
Pyrometer CellaTemp PX 61
Properties
Version
Measuring range
375 - 1200 °C
375 - 1200 °C
Focal range
0,12 m - ∞
0,12 m - ∞
Sight
Laser pilot light
Laser pilot light
Your selection will impact other settings.
Version
AF 21
Sight
Laser pilot light
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
More information about IO-Link:
Version
CellaTemp PX 61 AF 21
Measuring range
375 - 1200 °C
Focal range
0,12 m - ∞
Shape of the measuring field
round
Distance ratio
40 : 1
Measuring head
PA 41.05
Measuring principle
two-color
Sighting option
Laser pilot light
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer declaration
Pyrometer CellaTemp PX 61
Technical Data
Measurement parameters
Measuring range
375 - 1200 °C
Sensor
Double photodiode
Spectral range
1,5 / 1,9 µm
Response time t98
Messbereich 375 - 1200 °C:
≤ 20 ms (T > xxx °C)
Measurement uncertainty
1.5 % of temp. reading [°C]
Repeatability
3 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected measuring span
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Measuring heads
PA 41.05 (M16): focusing 0.12 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
2 x Open Collector 24 V DC, ≤ 150 mA
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA at 24 V DC
Equipment
Sighting option
Laser pilot light
Display
4 x 7 segments LED red, digit height 8 mm
Status display
4 x LED
Operator controls
3 pushbuttons
General parameters
Connection
M12 screw connection 5-pin
Ambient temperature
Electronics: 0 - 65 °C
Measuring head: 250 °C
Storage temperature
-20 - +80 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Electronics: Ø 65 mm x 187 mm
Measuring head: depending on the type
Housing material
Stainless steel V2A (1.4305)
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Smoothing filter
Memory operation mode
Holding time of the memory
Emissivity
Transmittance
Limit values and operating mode of the alarm contacts
Parameters of the ATD function
Simulation of current and temperature
Temperature unit °C/°F
Measuring channel two-colour, one-colour 1 and one-colour 2
Threshold value of the contamination monitoring
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Service function
Simulation of a measured value or a current signal
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PX
Connection cable VK 02/L AF 1 (5 m)
Measuring head
Operating manual (short)
* The fibre optic cable must be ordered separately.
Pyrometer CellaTemp PX 61
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PX 61
Downloads
Brochure CellaTemp PX
Brochure Flyer IO-Link
Manual CellaTemp PX 41
Quick guide CellaTemp PX 4x 5x 6x
Declaration of conformity Declaration of Conformity PXxx
UKCA Declaration of Conformity PXxx
EAC Deklaration PX
X
Pyrometer CellaTemp PX 61
Accessories
Software
Electrical accessories
Mechanical accessories
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Cable VK 01/Y AF 3
On Request
Cable VK 02/A AF 1
On Request
Cable VK 02/A AF 2
On Request
Cable VK 02/A AF 3
On Request
Cable VK 02/B
On Request
Cable VK 02/C AF 1
On Request
Cable VK 02/C AF 2
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Cooling jacket PA 20/B AF 1
On Request
Cooling jacket PA 20/M AF 1
On Request
Cooling jacket PA 20/M AF 2
On Request
Cooling jacket PA 20/M AF 3
On Request
Cooling jacket PA 20/M AF 4
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Digital display DA 230A
On Request
Emissivity switching box VK 30.07
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Interface converter SU 04 AF 1
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
IO-Link software SW 50 AF 1
Mounting bracket PA 11/K
On Request
Mounting bracket PA 11/U
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Opto-coupling SU 07 AF 1
On Request
Protective cap PA 20/K
On Request
Protective enclosure PA 40/B AF 1
On Request
Protective enclosure PA 40/M AF 1
On Request
Protective enclosure PA 40/M AF 2
On Request
Quick coupling PA 20/D
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Video cable VK 02/F AF 1
On Request
Video cable VK 02/F AF 2
On Request
Video cable VK 02/F AF 3
On Request
Pyrometer CellaTemp PX 61
IO-Link IODD
Type
Datei
Dateigröße
IODD PX61AF11-21-22_20241107.zip
1306 KB
Download
Pyrometer CellaTemp PX 61
IO-Link Manufacturer declaration
Type
Datei
Dateigröße
MC PX 61 AF 11 21 22_20241126_en.pdf
124 KB
Download
Pyrometer CellaTemp PX 61
Measurement field calculator
Pyrometer
PX 61 AF 21
(0,12 m - ∞)
PX 61 AF 21
(0,12 m - ∞)
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
4.8
9.6
14.4
19.2
24
28.8
33.6
38.4
43.2
48
52.8
57.6
62.4
67.2
72
76.8
81.6
86.4
91.2
96
100.8
105.6
110.4
115.2
120
3.00 mm
Measuring distance
Measuring field diameter
0.00 mm
9.20 mm
4.80 mm
8.95 mm
9.60 mm
8.70 mm
14.40 mm
8.46 mm
19.20 mm
8.21 mm
24.00 mm
7.96 mm
28.80 mm
7.71 mm
33.60 mm
7.46 mm
38.40 mm
7.22 mm
43.20 mm
6.97 mm
48.00 mm
6.72 mm
52.80 mm
6.47 mm
57.60 mm
6.22 mm
62.40 mm
5.98 mm
67.20 mm
5.73 mm
72.00 mm
5.48 mm
76.80 mm
5.23 mm
81.60 mm
4.98 mm
86.40 mm
4.74 mm
91.20 mm
4.49 mm
96.00 mm
4.24 mm
100.80 mm
3.99 mm
105.60 mm
3.74 mm
110.40 mm
3.50 mm
115.20 mm
3.25 mm
120.00 mm
3.00 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2025 –
Internetagentur
– Wrocklage Werbewerkstatt