Pyrometer
Product finder
Pyrometer CellaTemp PZ 10
Division KELLER
Merkliste
EN
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Tools
Tools
Measuring field calculator
Emissivity calculator
KITS app
Mounting combinations
Software CellaView
IO-Link Communication Tool
Support
Support
Product Data Sheets
FAQs
Warranty Information
Contact
Contact
Contact persons
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
Pyrometer CellaTemp PZ 10
Description
Special features:
Pyrometer CellaTemp PZ 10
Properties
Version
Measuring range
0 - 1000 °C
0 - 1000 °C
Focal distance
0,15 - 0,3 m
0,15 - 0,3 m
0,3 m - ∞
Sighting option
Through-the-lens-sighting
Through-the-lens-sighting
Laser pilot light
Your selection impact other settings.
Version
AF 401
AF 402
Sighting option
Through-the-lens-sighting
Laser pilot light
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PZ 10 AF 401
Version
CellaTemp PZ 10 AF 402
Measuring range
0 - 1000 °C
Measuring range
0 - 1000 °C
Focal distance
0,3 m - ∞
Focal distance
0,15 - 0,3 m
Shape of the measurement area
round
Distance ratio
40 : 1
Distance ratio
38 : 1
Objective
PZ 10.01
Objective
PZ 10.05
Measuring principle
one-colour
Sighting option
Through-the-lens-sighting
Sighting option
Laser pilot light
Technical Data
Downloads
Field-of-view calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaTemp PZ 10
Technical Data
Measurement parameters
Response time t90
≤ 100 ms
Optical variants
Lenses
Standard lens PZ focusing 0.3 m - ∞
Close-up lens PZ 10.05: focusing 0.15 m - 0.3 m
Pyrometer CellaTemp PZ 10
Emissivity calculator
Calculation of the emissivity to be set
From the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for types), the correct emissivity to be set on the pyrometer is calculated.
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PZ 10
Downloads
X
Pyrometer CellaTemp PZ 10
Accessories
Optical accessories
Mechanical accessories
Mountings
Adapter flange PB 08/J AF 1
On Request
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminium compact hose PB 08/L
On Request
Ball and socket mounting PZ 10/H
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Close-up optics PZ 10.05
On Request
Cooling jacket PZ 20/B AF 5
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Dust stop PZ 10/S
On Request
Dust stop PZ 10/S AF 2
On Request
Dust stop PZ 10/T
On Request
Fan PB 08/F AF 3
On Request
Fan PB 08/F AF 4
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange PZ 20/F-120
On Request
Flange PZ 20/F-120 DN50
On Request
Flange PZ 20/F-130
On Request
Flange PZ 20/F-145
On Request
Flange PZ 20/F-160
On Request
Flange PZ 20/F-50
On Request
Flange PZ 40/D
On Request
Flange PZ 40/N-130 AF 1
On Request
Flange PZ 40/N-130 AF 2
On Request
Flange tube PB 08/M AF1
On Request
Flange ZA 10/F-160
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting PB 08/K AF 2
On Request
Mounting PB 08/Q AF 1
On Request
Mounting PZ 20-080
On Request
Mounting PZ 20-093
On Request
Mounting PZ 20-095
On Request
Mounting socket PZ 20/G AF 1
On Request
Oscillating mirror PZ 20/X AF 5
On Request
Oscillating mirror PZ 20/X AF 6
On Request
Quick coupling PA 20/D
On Request
Quick coupling PA10/C
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Spherical flange PB 08/I AF 3
On Request
Spherical flange PB 08/I AF 4
On Request
Standard optics PZ 10.01
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Vorsatzlinsen für PZ 10 PZ 10/A
On Request
ZnS window PA 10/I
On Request
Pyrometer CellaTemp PZ 10
IO-Link IODD
Pyrometer CellaTemp PZ 10
IO-Link Manufacturer explanation
Pyrometer CellaTemp PZ 10
Field-of-view calculator
Pyrometer
PZ 10 AF 401
(0,3 m - ∞)
PZ 10 AF 402
(0,15 - 0,3 m)
PZ 10 AF 401
(0,3 m - ∞)
Supplementary lens
none
PZ 10/A
(0,036 - 0,042 m)
none
Focal distance
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
7.50 mm
Measuring distance
Spot diameter
0.00 mm
24.00 mm
12.00 mm
23.34 mm
24.00 mm
22.68 mm
36.00 mm
22.02 mm
48.00 mm
21.36 mm
60.00 mm
20.70 mm
72.00 mm
20.04 mm
84.00 mm
19.38 mm
96.00 mm
18.72 mm
108.00 mm
18.06 mm
120.00 mm
17.40 mm
132.00 mm
16.74 mm
144.00 mm
16.08 mm
156.00 mm
15.42 mm
168.00 mm
14.76 mm
180.00 mm
14.10 mm
192.00 mm
13.44 mm
204.00 mm
12.78 mm
216.00 mm
12.12 mm
228.00 mm
11.46 mm
240.00 mm
10.80 mm
252.00 mm
10.14 mm
264.00 mm
9.48 mm
276.00 mm
8.82 mm
288.00 mm
8.16 mm
300.00 mm
7.50 mm
Request a quote