Start page
Media library
watch list
Contact
Search
Log in
Cart
Suchergebnisse
Log in
User name/email
Password
Log in
Menu
Pyrometer
Product finder
Pyrometer CellaTemp PZ 20
Division KELLER
Media library
watch list
Contact
US
Company
Company
Publications
Application solutions
Pyrometer
Pyrometer
Pyro Series Instruments
PA series
PX series
PK series
PR series
PT series
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Annealing tapes
Oven
Combustion plant
Aluminum
Wood gluing
Semiconductor industry
Coking plant
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Software
Software
Software CellaView
IO-Link Communication Tool
Support
Support
FAQs
Contact
Contact
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Pyrometer CellaTemp PZ 20
Article description
Special features:
Pyrometer CellaTemp PZ 20
Properties
Version
Measuring range
250 - 2000 °C
250 - 2000 °C
Focal range
0,2 - 0,4 m
0,2 - 0,4 m
0,4 m - ∞
1,2 m - ∞
Sight
Through-the-lens sighting
Through-the-lens sighting
Laser pilot light
Your selection will impact other settings.
Version
AF 401
AF 402
AF 403
Sight
Through-the-lens sighting
Laser pilot light
You can request this article from us
Quantity:
Von der Merkliste entfernen
Add to watchlist
Request item
Version
CellaTemp PZ 20 AF 401
Version
CellaTemp PZ 20 AF 402
Version
CellaTemp PZ 20 AF 403
Measuring range
250 - 2000 °C
Measuring range
250 - 2000 °C
Measuring range
250 - 2000 °C
Focal range
0,4 m - ∞
Focal range
0,2 - 0,4 m
Focal range
1,2 m - ∞
Shape of the measuring field
round
Distance ratio
150 : 1
Distance ratio
140 : 1
Distance ratio
200 : 1
Objective
PZ 20.01
Objective
PZ 20.03
Objective
PZ 20.06
Measuring principle
one-color
Sighting option
Through-the-lens sighting
Sighting option
Laser pilot light
Technical Data
Downloads
Measurement field calculator
Accessories
Emissivity calculator
Application request
Pyrometer CellaTemp PZ 20
Technical Data
Measurement parameters
Measuring range
250 - 2,500 °C in sub-ranges
Sensor
Photodiode
Spectral range
1,1 - 1,7 μm
Response time t98
≤ 40 ms (T ≥ 750 °C)
Measurement uncertainty
0.75 % of temp. reading [°C]
Repeatability
1 K
Temperature coefficient
0.25 K/K (T < 500 °C)
0,05 %/K (T ≥ 500 °C)
Resolution interface
≤ 1 K
Optical variants
Objective lenses
both measuring ranges:
Standard objective lens PZ 20.01: focusing 0.4 m - ∞
Close-up lens PZ 20.03: focusing 0.2 m - 0.4 m
Wide-angle lens PZ 20.05: focusing 0.2 m - ∞
Telephoto lens PZ 20.06: focusing 1.2 m - ∞
additionally for measuring range 250 - 2,000 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Interface
Profibus DP
Power supply
22 - 27 VDC
Current consumption
≤ 80 mA
Equipment
Sighting option
through-the-lens sighting
Sighting option
Laser pilot light
General parameters
Connection
Screw terminals
Ambient temperature
0 - 60 °C
Storage temperature
-20 - +70 °C
Permissible air humidity
95 % RH max. (non-condensing)
Dimension
Ø 65 mm x 200 mm
Housing material
Aluminum
Type of protection
IP 65 acc. to DIN 40050
Weight
approx. 0.8 kg
Adjustable parameters
Parameters
Emissivity 10 to 99%; increment 1 %
Smoothing filter
Min./Max. peak picker
Double max. memory with adjustable holding time
Device address
Temperature unit °C/°F
Diagnostic function
Functions
Overtemperature signal
if the internal temperature exceeds 65 °C, the analog output shows a value > 20.5 mA
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PZ
Operating manual
GSD file on CD
Pyrometer CellaTemp PZ 20
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset at the pyrometer and the ambient temperature (required for some instrument types).
Calculation of the measured value
The value displayed by the pyrometer is calculated from the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for some instrument types).
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Value measured by the pyrometer
Pyrometer
Quotient
Two-color mode
One-color 1
One-color 2
Preset emissivity
-
+
Value measured by the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PZ 20
Downloads
Declaration of conformity Declaration of Conformity PZ-Prof
UKCA Declaration of Conformity PZ-Prof
X
Pyrometer CellaTemp PZ 20
Accessories
Optical accessories
Mechanical accessories
Mounting solutions
Adapter flange PZ 20/H
On Request
Adapter ring PZ 20/E
On Request
Air purge PZ 20/A AF 1
On Request
Aluminum compact hose PB 08/L
On Request
Ball and socket mount PZ 10/H
On Request
Clamping collar PZ 20/L AF 2
On Request
Clamping collar PZ 20/N AF 2
On Request
Close-up optics PZ 20.03
On Request
Cooling jacket PZ 20/B AF 5
On Request
Deflection mirror PA 20/E AF 1
On Request
Deflection mirror PA 20/E AF 2
On Request
Dust stop PZ 20/S
On Request
Dust stop PZ 20/T
On Request
Fan PB 08/F AF 3
On Request
Flange PB 08/R AF 1
On Request
Flange PB 08/R AF 2
On Request
Flange PK 20/F-70
On Request
Flange tube PB 08/M AF1
On Request
Holder PB 08/K AF 2
On Request
Holder PB 08/Q AF 1
On Request
Hose clamp
On Request
Hose clamp 0
On Request
Illumination ring PZ 10/P
On Request
Industrial hose GP 40
On Request
Intermediate tube PZ 20/C
On Request
Intermediate tube PZ 20/J
On Request
Intermediate tube PZ 40/C
On Request
Lens PZ 20.08
On Request
Mounting bracket PZ 20/U AF 2
On Request
Mounting combinations PZ 20-067
On Request
Mounting combinations PZ 20-080
On Request
Mounting combinations PZ 20-092
On Request
Mounting combinations PZ 20-095
On Request
Mounting combinations PZ 20-096
On Request
Mounting combinations PZ 20-097
On Request
Mounting combinations PZ 20-098
On Request
Mounting combinations PZ 20-099
On Request
Mounting combinations PZ 20-100
On Request
Mounting combinations PZ 20-101
On Request
Mounting combinations PZ 20-102
On Request
Mounting combinations PZ 40-014
On Request
Mounting flange PZ 20/F-120
On Request
Mounting flange PZ 20/F-120 DN50
On Request
Mounting flange PZ 20/F-130
On Request
Mounting flange PZ 20/F-145
On Request
Mounting flange PZ 20/F-160
On Request
Mounting flange PZ 20/F-50
On Request
Mounting flange PZ 40/D
On Request
Mounting flange PZ 40/N-130 AF 1
On Request
Quartz protective window 70146
On Request
Quartz window PA 20/I
On Request
Quartz window with hinge PZ 20/I AF 1
On Request
Quick coupling PA 20/C
On Request
Quick coupling PA 20/D
On Request
Servo mirror PZ 20/X AF 5
On Request
Servo mirror PZ 20/X AF 6
On Request
Shaft nut 0
On Request
Spherical flange PB 08/I
On Request
Spherical flange PB 08/I AF 2
On Request
Standard optics PZ 20.01
On Request
Supplementary lens PZ 20/O-120
On Request
Supplementary lens PZ 20/O-75
On Request
Tele-optics PZ 20.06
On Request
Thermal insulating tube PZ 20/K
On Request
Threaded ring 0
On Request
Toggle adapter PZ 40/G
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-50
On Request
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-63
On Request
Wide-angle optics PZ 20.05
On Request
Pyrometer CellaTemp PZ 20
IO-Link IODD
Pyrometer CellaTemp PZ 20
IO-Link Manufacturer declaration
Pyrometer CellaTemp PZ 20
Measurement field calculator
Pyrometer
PZ 20 AF 401
(0,4 m - ∞)
PZ 20 AF 402
(0,2 - 0,4 m)
PZ 20 AF 403
(1,2 m - ∞)
PZ 20 AF 404
(0,2 m - ∞)
PZ 20 AF 405
(0,4 m - ∞)
PZ 20 AF 406
(0,2 - 0,4 m)
PZ 20 AF 407
(1,2 m - ∞)
PZ 20 AF 408
(0,2 m - ∞)
PZ 20 AF 409
(0,3 m - ∞)
PZ 20 AF 401
(0,4 m - ∞)
Supplementary lens
none
PZ 20/0-50
(0,036 - 0,041 m)
PZ 20/O-63
(0,045 - 0,054 m)
PZ 20/O-75
(0,052 - 0,063 m)
PZ 20/O-120
(0,084 - 0,112 m)
none
Focal range
mm
Length of the graph
mm
Calculate
Print
Measuring distance (mm)
0
32
64
96
128
160
192
224
256
288
320
352
384
2.67 mm
Measuring distance
Measuring field diameter
0.00 mm
18.00 mm
16.00 mm
17.39 mm
32.00 mm
16.77 mm
48.00 mm
16.16 mm
64.00 mm
15.55 mm
80.00 mm
14.93 mm
96.00 mm
14.32 mm
112.00 mm
13.71 mm
128.00 mm
13.09 mm
144.00 mm
12.48 mm
160.00 mm
11.87 mm
176.00 mm
11.25 mm
192.00 mm
10.64 mm
208.00 mm
10.03 mm
224.00 mm
9.41 mm
240.00 mm
8.80 mm
256.00 mm
8.19 mm
272.00 mm
7.57 mm
288.00 mm
6.96 mm
304.00 mm
6.35 mm
320.00 mm
5.73 mm
336.00 mm
5.12 mm
352.00 mm
4.51 mm
368.00 mm
3.89 mm
384.00 mm
3.28 mm
400.00 mm
2.67 mm
Request a quote
back
Checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt