EN
language choice
Search
Login
Cart
Menu
Please choose your language:
Search results
Log in
User name/E-mail
Password
Log in
Application solutions
Aluminium
Casting carousel
Coil gap
Extruder press
Forge
Press hardening
Building materials
Asphalt
Cement
Concrete
Lime
carbon · carbon black
Carbon · graphite · graphene
Combustion plant
Biomass power plant
Coal-fired power plant
Hazardous waste incineration
Sewage sludge incineration
Waste incineration
Crystal growing
artificial diamonds
Czochralski process
Multi-crystalline silicon
PVT (SiC)
Siemens process
Extruder press
Extruder press
Gas furnace
Forge
Die hammer forging
Drop forging
Foundry
Centrifugal casting
Mould casting
Furnace
Continuous furnace
Gas furnace
High temperature furnace
Rotary kiln, directly heated
Rotary kiln, indirectly heated
Tunnel kiln
Vacuum furnace
Glass
Container glass
Float glass
Induction
Brazing
Extruder press
Forge
Hardening + annealing
Tube bending
Paper
Lime
Research and Development
Calibration
Filaments
Glow strip
Mass Spectrometer
Safety applications
Coil storage
Semiconductor manufacturing
MBE (Molecular Beam Epitaxy)
PLD (Pulsed Laser Deposition)
RTP (Rapid Thermal Processing)
Steel
Blast furnace
Coking plant
Continuous annealing line
Continuous casting
Rod rolling mill
Rolling mill
Rolling mill cooling bed
Sinter plans
Strip galvanizing
Torpedo car
Tube rolling mill
Wire rolling mill
Products
Pyrometers
PX series
PA series
PK series
PR series
PT series
Mikro series
Product finder
Measuring systems
Accessories
Mounting combinations
Publications
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Glow strips
Tunnel kiln
Combustion plant
Aluminium
Wood gluing
Semiconductor industry
Services
Tools
Measuring field calculator
Emissivity calculator
Troubleshooting
Software
Software CellaView
IO-Link Communication Tool
IO-Link
KITS Service App
Glossary
Pyrometer
Media center
Videos
Company
About us
Division Keller
Purchase
Corporate policy / Certificates
Locations
Company history
News
Jobs + Career
Contact persons
Keller as an employer
Privacy Policy for Applicants
Events
Contact
Measuring system PA 60-K002
Pyrometer Systems
Products
Pyrometers
PA series
Measuring system PA 60-K002
Measuring system consisting of:
Pyrometer CellaTemp PA 60 AF 1
Mounting PA 20-071
Quartz protective window 70146
Measuring system PA 60-K002
You can request this article from us
Quantity:
Request article
Version
CellaTemp PA 60-K002
Measuring range
300 - 800 °C
Focus distance
0,3 m - ∞
Shape of the measuring field
round
Distance ratio
39 : 1
Objective
PZ 20.08
Measuring principle
two-colour
Sighting option
Laser pilot light
Technical Data
Downloads
Measuring field calculator
Accessories
Emissivity calculator
Application request
Measuring system PA 60-K002
Technical Data
Measurement parameters
Measuring range
300 - 1000 °C in several segments
Sensor
Double photo diode
Spectral range
1.50 / 1.90 μm
Response time t98
≤ 30 ms
Measurement uncertainty
1 % of temp. reading [°C]
Repeatability
2 K
Temperature coefficient
0.05 %/K
Resolution current output
0.2 K + 0.03 % of selected range
Resolution interface
0.1 K
Resolution display
1 K
Optical variants
Lenses
Messbereich 300 - 800 °C:
Objektiv F50 PZ 20.08: Fokussierung 0,3 m - ∞
Messbereich 400 - 1000 °C:
Standard lens PZ 20.01: focusing 0.4 m - ∞
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Analog input
0 - 10 V
Switching output
2 x Open Collector 24 V DC, ≤ 30 mA
Switching input
2 x to 24 V
Interface
USB
Interface
RS 485
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 175 mA for 24 V DC
Camera
Video output
Composite PAL, 1 Vpp, 75 Ω
Features
Sighting option
Through-the-lens-sighting
Sighting option
Laser pilot light
Sighting option
Camera
Display
4-digit LED display red, digit-height 8 mm
Status display
2 x LED
Control elements
3 buttons
General parameters
Connection
M12 thread 8-pin connection
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 65 mm x 220 mm (max. 277 mm)
Housing
Stainless steel V2A (1.4305)
Protection class
IP 65 acc. to DIN 40050
Weight
approx. 0.9 kg
Adjustable parameters
Parameters
Measuring range
Measured variable and scale of analogue input and output signals
Smoothing filter
Memory operation mode
Hold time of the memory
Emissivity
Transmittance
Compensation of the reflected ambient radiation
Limits and operating mode of the alarm contacts
Parameters of the ATD function (optional)
Linearization function
Status display of the LEDs
Simulation of current and temperature
Temperature unit °C/°F
Measurement channel two-colour, single-colour 1 and single-colour 2
Threshold level of the contamination monitoring
in addition, for model with camera:
TBC function
White balance
Functions
Overtemperature signal
if the internal temperature exceeds 80 °C the analogue output shows a value > 20.5 mA
Service function
Simulation of a measured value or a current signal
ATD-(Automatic Temperature Detection) function
Automatic temperature detection at discontinuous processes
Scope of delivery
Scope of delivery
Pyrometer CellaTemp PA
Connection cable VK 02/A (5 m)
Video cable VK 02/F (5 m) for model with built-in camera
USB cable VK 11/D (1.8 m)
Software CellaView
Manual (short)
Software
Software
CellaView
Measuring system PA 60-K002
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset on the pyrometer and the ambient temperature (necessary for some types).
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Measuring system PA 60-K002
Downloads
Brochure CellaTemp PA
Brochure Supplementary lenses
Brochure CellaView
Manual CellaTemp PA 4x5x6x
Drawing PA 60-K002
Declaration of conformity Declaration from Conformity PAxx
UKCA Declaration from Conformity PAxx
EAC Deklaration PK-PA-PT
X
Measuring system PA 60-K002
Accessories
Electrical accessories
Optical accessories
Mechanical accessories
Mountings
Accessories for interfaces SU 02 AF 1
Upon request
Adapter flange PZ 20/H
Add to Cart
Adapter ring PZ 20/E
Add to Cart
Air purge PZ 20/A AF 1
Add to Cart
Aluminium compact hose PB 08/L
Add to Cart
Attachment lens PZ 20/O-120
Add to Cart
Attachment lens PZ 20/O-75
Add to Cart
Ball and socket mounting PZ 10/H
Add to Cart
Cable VK 01/Y AF 3
Add to Cart
Cable VK 02/A AF 1
Add to Cart
Cable VK 02/A AF 2
Add to Cart
Cable VK 02/A AF 3
Add to Cart
Cable VK 02/B
Add to Cart
Cable VK 02/C AF 1
Add to Cart
Cable VK 02/C AF 2
Add to Cart
Clamping collar PZ 20/L AF 2
Add to Cart
Clamping collar PZ 20/N AF 2
Add to Cart
Close-up optics PZ 20.03
Add to Cart
Cooling jacket PA 20/B AF 1
Add to Cart
Cooling jacket PA 20/M AF 1
Add to Cart
Cooling jacket PA 20/M AF 2
Add to Cart
Cooling jacket PA 20/M AF 3
Add to Cart
Cooling jacket PA 20/M AF 4
Add to Cart
Deflection mirror PA 20/E AF 1
Add to Cart
Deflection mirror PA 20/E AF 2
Add to Cart
Digital display DA 230A
Upon request
Dust stop PZ 10/S
Add to Cart
Dust stop PZ 10/T
Add to Cart
Emissivity switching box VK 30.07
Add to Cart
Fan PB 08/F AF 3
Add to Cart
Flange PB 08/R AF 1
Add to Cart
Flange PB 08/R AF 2
Add to Cart
Flange PK 20/F-70
Add to Cart
Flange tube PB 08/M AF1
Add to Cart
Hose clamp
Upon request
Hose clamp
Add to Cart
Illumination ring PZ 10/P
Add to Cart
Industrial hose GP 40
Add to Cart
Interface converter SU 04 AF 1
Add to Cart
Interface isolator SU 07 AF 1
Add to Cart
Intermediate tube PZ 20/C
Add to Cart
Intermediate tube PZ 20/J
Add to Cart
Intermediate tube PZ 40/C
Add to Cart
Junction box VK 30.02
Add to Cart
Lens system PZ 20.08
Add to Cart
Monitor system 0
Add to Cart
Mounting angle PA 11/K
Add to Cart
Mounting bracket PA 11/U
Add to Cart
Mounting bracket PZ 20/U AF 2
Add to Cart
Mounting flange PZ 20/F-120
Add to Cart
Mounting flange PZ 20/F-120 DN50
Add to Cart
Mounting flange PZ 20/F-130
Add to Cart
Mounting flange PZ 20/F-145
Add to Cart
Mounting flange PZ 20/F-160
Add to Cart
Mounting flange PZ 20/F-50
Add to Cart
Mounting flange PZ 40/D
Add to Cart
Mounting flange PZ 40/N-130 AF 1
Add to Cart
Mounting PA 20-005
Upon request
Mounting PA 20-010
Upon request
Mounting PA 20-012
Upon request
Mounting PA 20-014
Upon request
Mounting PA 20-015
Upon request
Mounting PA 20-024
Upon request
Mounting PA 20-027
Upon request
Mounting PA 20-028
Upon request
Mounting PA 20-036
Upon request
Mounting PA 20-037
Upon request
Mounting PA 20-048
Upon request
Mounting PA 20-050
Upon request
Mounting PA 20-052
Upon request
Mounting PA 20-054
Upon request
Mounting PA 20-058
Upon request
Mounting PA 20-059
Upon request
Mounting PA 20-060
Upon request
Mounting PA 20-062
Upon request
Mounting PA 20-064
Upon request
Mounting PA 20-066
Upon request
Mounting PA 20-071
Upon request
Mounting PA 20-073
Upon request
Mounting PA 20-077
Upon request
Mounting PA 20-080
Upon request
Mounting PA 20-081
Upon request
Mounting PA 20-091
Upon request
Mounting PA 20-098
Upon request
Mounting PA 20-100
Upon request
Mounting PA 20-103
Upon request
Mounting PA 20-107
Upon request
Mounting PA 20-112
Upon request
Mounting PA 20-117
Upon request
Mounting PA 20-122
Upon request
Mounting PA 83-002
Upon request
Mounting PA 83-007
Upon request
Mounting PA 83-010
Upon request
Mounting PA 83-011
Upon request
Mounting PB 08/K AF 2
Add to Cart
Mounting PB 08/Q AF 1
Add to Cart
Oscillating mirror PZ 20/X AF 5
Add to Cart
Oscillating mirror PZ 20/X AF 6
Add to Cart
Polarisation filter PA 20/P
Add to Cart
Protective cap PA 20/K
Add to Cart
Protective enclosure PA 40/B AF 1
Add to Cart
Protective enclosure PA 40/M AF 1
Add to Cart
Protective enclosure PA 40/M AF 2
Add to Cart
Quartz protective window 70146
Add to Cart
Quartz window PA 20/I
Add to Cart
Quartz window with hinge PZ 20/I AF 1
Add to Cart
Quick coupling PA 20/C
Add to Cart
Quick coupling PA 20/D
Add to Cart
Shaft nut
Add to Cart
Spherical flange PB 08/I
Add to Cart
Spherical flange PB 08/I AF 2
Add to Cart
Standard optics PZ 20.01
Add to Cart
Tele-optics PZ 20.06
Add to Cart
Thermal insulating tube PZ 20/K
Add to Cart
Threaded ring
Add to Cart
Toggle adapter PZ 40/G
Add to Cart
Video cable VK 02/F AF 1
Add to Cart
Video cable VK 02/F AF 2
Add to Cart
Video cable VK 02/F AF 3
Add to Cart
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-50
Add to Cart
Vorsatzlinse für PZ 20 - 50, PA 20 - 40 PZ 20/O-63
Add to Cart
Wide-angle optics PZ 20.05
Add to Cart
Measuring system PA 60-K002
IO-Link IODD
Measuring system PA 60-K002
IO-Link Manufacturer explanation
Measuring system PA 60-K002
Measuring field calculator
Pyrometer
PA 60 AF 1
Focus distance
mm
Graphic length
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
7.69 mm
Measuring distance
Measuring field diameter
0.00 mm
24.50 mm
12.00 mm
23.83 mm
24.00 mm
23.16 mm
36.00 mm
22.48 mm
48.00 mm
21.81 mm
60.00 mm
21.14 mm
72.00 mm
20.47 mm
84.00 mm
19.79 mm
96.00 mm
19.12 mm
108.00 mm
18.45 mm
120.00 mm
17.78 mm
132.00 mm
17.10 mm
144.00 mm
16.43 mm
156.00 mm
15.76 mm
168.00 mm
15.09 mm
180.00 mm
14.42 mm
192.00 mm
13.74 mm
204.00 mm
13.07 mm
216.00 mm
12.40 mm
228.00 mm
11.73 mm
240.00 mm
11.05 mm
252.00 mm
10.38 mm
264.00 mm
9.71 mm
276.00 mm
9.04 mm
288.00 mm
8.36 mm
300.00 mm
7.69 mm